Progress in the CMS ECAL
The CMS electromagnetic calorimeter design goal is to be precise and accurate enough to detect the Higgs to 2 photons signal over a continuous background. A resolution better than 1% for showers of 50-100 GeV is required. To achieve this goal, all the factors that can eventually spoil the calorimete...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)01246-8 http://cds.cern.ch/record/512969 |
Sumario: | The CMS electromagnetic calorimeter design goal is to be precise and accurate enough to detect the Higgs to 2 photons signal over a continuous background. A resolution better than 1% for showers of 50-100 GeV is required. To achieve this goal, all the factors that can eventually spoil the calorimeter resolution have to be taken into account. This includes: careful measurements and control of crystal properties before installation, precise calibration of each crystal with an electron beam before use in CMS and accurate off-line reconstruction of the electromagnetic showers. The importance of these items and the progress achieved will be discussed. (6 refs). |
---|