Cargando…
Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS
To obtain full charge collection the CMS silicon detectors should be able to operate at high bias voltage. We observed that multiguard structures enhance the breakdown performance of the devices on several tens of baby detectors designed for CMS. The beneficial effects of the multiguard structures s...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)01207-9 http://cds.cern.ch/record/512977 |
_version_ | 1780897542260654080 |
---|---|
author | Bacchetta, N Bisello, D Candelori, A Da Rold, M Descovich, M Kaminski, A Messineo, A Rizzo, F Verzellesi, G |
author_facet | Bacchetta, N Bisello, D Candelori, A Da Rold, M Descovich, M Kaminski, A Messineo, A Rizzo, F Verzellesi, G |
author_sort | Bacchetta, N |
collection | CERN |
description | To obtain full charge collection the CMS silicon detectors should be able to operate at high bias voltage. We observed that multiguard structures enhance the breakdown performance of the devices on several tens of baby detectors designed for CMS. The beneficial effects of the multiguard structures still remains after the strong neutron irradiation performed to simulate the operation at the LHC. (3 refs). |
id | cern-512977 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5129772019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)01207-9http://cds.cern.ch/record/512977engBacchetta, NBisello, DCandelori, ADa Rold, MDescovich, MKaminski, AMessineo, ARizzo, FVerzellesi, GImprovement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMSDetectors and Experimental TechniquesTo obtain full charge collection the CMS silicon detectors should be able to operate at high bias voltage. We observed that multiguard structures enhance the breakdown performance of the devices on several tens of baby detectors designed for CMS. The beneficial effects of the multiguard structures still remains after the strong neutron irradiation performed to simulate the operation at the LHC. (3 refs).oai:cds.cern.ch:5129772001 |
spellingShingle | Detectors and Experimental Techniques Bacchetta, N Bisello, D Candelori, A Da Rold, M Descovich, M Kaminski, A Messineo, A Rizzo, F Verzellesi, G Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS |
title | Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS |
title_full | Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS |
title_fullStr | Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS |
title_full_unstemmed | Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS |
title_short | Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS |
title_sort | improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for cms |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)01207-9 http://cds.cern.ch/record/512977 |
work_keys_str_mv | AT bacchettan improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT bisellod improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT candeloria improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT daroldm improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT descovichm improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT kaminskia improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT messineoa improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT rizzof improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms AT verzellesig improvementinbreakdowncharacteristicswithmultiguardstructuresinmicrostripsilicondetectorsforcms |