Cargando…
The response of the Sievert instrument in neutron beams up to 180 MeV
Measurements with a tissue-equivalent proportional counter (TEPC) using the variance-covariance method have been performed in neutron beams between 71 keV and 180 MeV and in the cosmic radiation reference field (CERF) at CERN. The results show that with appropriate linear Q/sub D/(y/sub D/) relation...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/516160 |
_version_ | 1780897623805263872 |
---|---|
author | Kylionen, J E Lindborg, L Samuelson, G |
author_facet | Kylionen, J E Lindborg, L Samuelson, G |
author_sort | Kylionen, J E |
collection | CERN |
description | Measurements with a tissue-equivalent proportional counter (TEPC) using the variance-covariance method have been performed in neutron beams between 71 keV and 180 MeV and in the cosmic radiation reference field (CERF) at CERN. The results show that with appropriate linear Q/sub D/(y/sub D/) relations, the ambient dose equivalent can be determined within about 55% in these beams. Build- up measurements show that wall thickness is not crucial for H* determinations at 60 and 180 MeV. (26 refs). |
id | cern-516160 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5161602019-09-30T06:29:59Zhttp://cds.cern.ch/record/516160engKylionen, J ELindborg, LSamuelson, GThe response of the Sievert instrument in neutron beams up to 180 MeVHealth Physics and Radiation EffectsMeasurements with a tissue-equivalent proportional counter (TEPC) using the variance-covariance method have been performed in neutron beams between 71 keV and 180 MeV and in the cosmic radiation reference field (CERF) at CERN. The results show that with appropriate linear Q/sub D/(y/sub D/) relations, the ambient dose equivalent can be determined within about 55% in these beams. Build- up measurements show that wall thickness is not crucial for H* determinations at 60 and 180 MeV. (26 refs).oai:cds.cern.ch:5161602001 |
spellingShingle | Health Physics and Radiation Effects Kylionen, J E Lindborg, L Samuelson, G The response of the Sievert instrument in neutron beams up to 180 MeV |
title | The response of the Sievert instrument in neutron beams up to 180 MeV |
title_full | The response of the Sievert instrument in neutron beams up to 180 MeV |
title_fullStr | The response of the Sievert instrument in neutron beams up to 180 MeV |
title_full_unstemmed | The response of the Sievert instrument in neutron beams up to 180 MeV |
title_short | The response of the Sievert instrument in neutron beams up to 180 MeV |
title_sort | response of the sievert instrument in neutron beams up to 180 mev |
topic | Health Physics and Radiation Effects |
url | http://cds.cern.ch/record/516160 |
work_keys_str_mv | AT kylionenje theresponseofthesievertinstrumentinneutronbeamsupto180mev AT lindborgl theresponseofthesievertinstrumentinneutronbeamsupto180mev AT samuelsong theresponseofthesievertinstrumentinneutronbeamsupto180mev AT kylionenje responseofthesievertinstrumentinneutronbeamsupto180mev AT lindborgl responseofthesievertinstrumentinneutronbeamsupto180mev AT samuelsong responseofthesievertinstrumentinneutronbeamsupto180mev |