Cargando…
Micro-gap parallel-plate chambers with porous secondary electron emitters
We developed a micro-gap (0.1 mm) parallel-plate chamber with one or more layers of solid converters of radiation. The detector with a one-layer converter was tested with X-rays (6-30 keV) and also at the T9 and T10 beam facilities at CERN. A position resolution better than 30 mu m was achieved. Wit...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00838-X http://cds.cern.ch/record/516194 |
_version_ | 1780897628567896064 |
---|---|
author | Fonte, Paulo J R Peskov, Vladimir |
author_facet | Fonte, Paulo J R Peskov, Vladimir |
author_sort | Fonte, Paulo J R |
collection | CERN |
description | We developed a micro-gap (0.1 mm) parallel-plate chamber with one or more layers of solid converters of radiation. The detector with a one-layer converter was tested with X-rays (6-30 keV) and also at the T9 and T10 beam facilities at CERN. A position resolution better than 30 mu m was achieved. With minimum ionizing particles, an efficiency close to ~20% was achieved with one detector, and it was almost twice as high as the efficiency due to the interaction of minimum ionizing particles with the gas alone. The detectors with a few layers of converter were tested only with X-rays. An efficiency of ~10% could be achieved. The combination of a micro-gap PPC with secondary- electron converters may allow a further improvement of the time resolution of these detectors, which has already reached 50-100 ps at present. (10 refs). |
id | cern-516194 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-5161942019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00838-Xhttp://cds.cern.ch/record/516194engFonte, Paulo J RPeskov, VladimirMicro-gap parallel-plate chambers with porous secondary electron emittersDetectors and Experimental TechniquesWe developed a micro-gap (0.1 mm) parallel-plate chamber with one or more layers of solid converters of radiation. The detector with a one-layer converter was tested with X-rays (6-30 keV) and also at the T9 and T10 beam facilities at CERN. A position resolution better than 30 mu m was achieved. With minimum ionizing particles, an efficiency close to ~20% was achieved with one detector, and it was almost twice as high as the efficiency due to the interaction of minimum ionizing particles with the gas alone. The detectors with a few layers of converter were tested only with X-rays. An efficiency of ~10% could be achieved. The combination of a micro-gap PPC with secondary- electron converters may allow a further improvement of the time resolution of these detectors, which has already reached 50-100 ps at present. (10 refs).oai:cds.cern.ch:5161942000 |
spellingShingle | Detectors and Experimental Techniques Fonte, Paulo J R Peskov, Vladimir Micro-gap parallel-plate chambers with porous secondary electron emitters |
title | Micro-gap parallel-plate chambers with porous secondary electron emitters |
title_full | Micro-gap parallel-plate chambers with porous secondary electron emitters |
title_fullStr | Micro-gap parallel-plate chambers with porous secondary electron emitters |
title_full_unstemmed | Micro-gap parallel-plate chambers with porous secondary electron emitters |
title_short | Micro-gap parallel-plate chambers with porous secondary electron emitters |
title_sort | micro-gap parallel-plate chambers with porous secondary electron emitters |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)00838-X http://cds.cern.ch/record/516194 |
work_keys_str_mv | AT fontepaulojr microgapparallelplatechamberswithporoussecondaryelectronemitters AT peskovvladimir microgapparallelplatechamberswithporoussecondaryelectronemitters |