Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases

Noble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or particles. This signal can be used for several purposes, for example as a start signal for TPCs or for particles identifica...

Descripción completa

Detalles Bibliográficos
Autores principales: Periale, L, Peskov, Vladimir, Carlson, P J, Francke, T, Iacobaeus, C, Pavlopoulos, P, Pietropaolo, F, Sokolova, T
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/518419
_version_ 1780897721147719680
author Periale, L
Peskov, Vladimir
Carlson, P J
Francke, T
Iacobaeus, C
Pavlopoulos, P
Pietropaolo, F
Sokolova, T
author_facet Periale, L
Peskov, Vladimir
Carlson, P J
Francke, T
Iacobaeus, C
Pavlopoulos, P
Pietropaolo, F
Sokolova, T
author_sort Periale, L
collection CERN
description Noble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or particles. This signal can be used for several purposes, for example as a start signal for TPCs or for particles identification. Usually photomultipliers (PMs) are used for the detection of the scintillation light. In our previous work we have demonstrated that costly PMs could be replaced by gaseous detectors with CsI photocathodes . Such detectors have the same quantum efficiency as the best PMs but at the same time are cheap, simple and have high position and time resolutions. The aim of this work is to evaluate various planar type gaseous detectors with CsI photocahodes in order to choose the best one for the detection of the primary scintillation light from noble gases and liquids.
id cern-518419
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5184192019-09-30T06:29:59Zhttp://cds.cern.ch/record/518419engPeriale, LPeskov, VladimirCarlson, P JFrancke, TIacobaeus, CPavlopoulos, PPietropaolo, FSokolova, TEvaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gasesOther Fields of PhysicsNoble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or particles. This signal can be used for several purposes, for example as a start signal for TPCs or for particles identification. Usually photomultipliers (PMs) are used for the detection of the scintillation light. In our previous work we have demonstrated that costly PMs could be replaced by gaseous detectors with CsI photocathodes . Such detectors have the same quantum efficiency as the best PMs but at the same time are cheap, simple and have high position and time resolutions. The aim of this work is to evaluate various planar type gaseous detectors with CsI photocahodes in order to choose the best one for the detection of the primary scintillation light from noble gases and liquids.physics/0106070oai:cds.cern.ch:5184192001-06-21
spellingShingle Other Fields of Physics
Periale, L
Peskov, Vladimir
Carlson, P J
Francke, T
Iacobaeus, C
Pavlopoulos, P
Pietropaolo, F
Sokolova, T
Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases
title Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases
title_full Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases
title_fullStr Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases
title_full_unstemmed Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases
title_short Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases
title_sort evaluation of various planar gaseous detectors with csi photocathodes for the detection of primary scintillation light from noble gases
topic Other Fields of Physics
url http://cds.cern.ch/record/518419
work_keys_str_mv AT perialel evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT peskovvladimir evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT carlsonpj evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT francket evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT iacobaeusc evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT pavlopoulosp evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT pietropaolof evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases
AT sokolovat evaluationofvariousplanargaseousdetectorswithcsiphotocathodesforthedetectionofprimaryscintillationlightfromnoblegases