Cargando…

Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE

This work describes an alternative to the current ALICE baseline solution for a TO detector, still under development. The proposed system consists of two MCP-based T0/Centrality Start Detectors (backward-forward isochronous disks) equipped with programmable, TTC synchronized front-end electronic car...

Descripción completa

Detalles Bibliográficos
Autores principales: Efimov, L G, Feofilov, G A, Kondratev, V A, Lenti, V, Lyapin, V G, Stolyarov, O I, Trzaska, W H, Tsimbal, F A, Tulina, T A, Valiev, F F, Villalobos Baillie, O, Vinogradov, L I
Lenguaje:eng
Publicado: CERN 2001
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2001-005.273
http://cds.cern.ch/record/521855
_version_ 1780897804972982272
author Efimov, L G
Feofilov, G A
Kondratev, V A
Lenti, V
Lyapin, V G
Stolyarov, O I
Trzaska, W H
Tsimbal, F A
Tulina, T A
Valiev, F F
Villalobos Baillie, O
Vinogradov, L I
author_facet Efimov, L G
Feofilov, G A
Kondratev, V A
Lenti, V
Lyapin, V G
Stolyarov, O I
Trzaska, W H
Tsimbal, F A
Tulina, T A
Valiev, F F
Villalobos Baillie, O
Vinogradov, L I
author_sort Efimov, L G
collection CERN
description This work describes an alternative to the current ALICE baseline solution for a TO detector, still under development. The proposed system consists of two MCP-based T0/Centrality Start Detectors (backward-forward isochronous disks) equipped with programmable, TTC synchronized front-end electronic cards (FEECs) which would be positioned along the LHC colliding beam line on both sides of the ALICE interaction region. The purpose of this arrangement, providing both precise timing and fast multiplicity selection, is to give a pre-trigger signal at the earliest possible time after a central event. This pre-trigger can be produced within 25 ns. It can be delivered within 100 ns directly to the Transition Radiation Detector and would be the earliest L0 input coming to the ALICE Central Trigger Processor. A noise-free passive multichannel summator of 2ns signals is used to provide a determination of the collision time with a potential accuracy better than 10 ps in the case of Pb-Pb collisions, the limit coming from the electronics. Results from in-beam tests confirm the functionality of the main elements. Further development plans are presented.
id cern-521855
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
publisher CERN
record_format invenio
spelling cern-5218552019-09-30T06:29:59Zdoi:10.5170/CERN-2001-005.273http://cds.cern.ch/record/521855engEfimov, L GFeofilov, G AKondratev, V ALenti, VLyapin, V GStolyarov, O ITrzaska, W HTsimbal, F ATulina, T AValiev, F FVillalobos Baillie, OVinogradov, L IFast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICEDetectors and Experimental TechniquesThis work describes an alternative to the current ALICE baseline solution for a TO detector, still under development. The proposed system consists of two MCP-based T0/Centrality Start Detectors (backward-forward isochronous disks) equipped with programmable, TTC synchronized front-end electronic cards (FEECs) which would be positioned along the LHC colliding beam line on both sides of the ALICE interaction region. The purpose of this arrangement, providing both precise timing and fast multiplicity selection, is to give a pre-trigger signal at the earliest possible time after a central event. This pre-trigger can be produced within 25 ns. It can be delivered within 100 ns directly to the Transition Radiation Detector and would be the earliest L0 input coming to the ALICE Central Trigger Processor. A noise-free passive multichannel summator of 2ns signals is used to provide a determination of the collision time with a potential accuracy better than 10 ps in the case of Pb-Pb collisions, the limit coming from the electronics. Results from in-beam tests confirm the functionality of the main elements. Further development plans are presented.CERNCERN-ALI-2001-027CERN-ALICE-PUB-2001-27oai:cds.cern.ch:5218552001-10-09
spellingShingle Detectors and Experimental Techniques
Efimov, L G
Feofilov, G A
Kondratev, V A
Lenti, V
Lyapin, V G
Stolyarov, O I
Trzaska, W H
Tsimbal, F A
Tulina, T A
Valiev, F F
Villalobos Baillie, O
Vinogradov, L I
Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE
title Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE
title_full Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE
title_fullStr Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE
title_full_unstemmed Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE
title_short Fast Pre-Trigger Electronics of T0/Centrality MCP-Based Start Detector for ALICE
title_sort fast pre-trigger electronics of t0/centrality mcp-based start detector for alice
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.5170/CERN-2001-005.273
http://cds.cern.ch/record/521855
work_keys_str_mv AT efimovlg fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT feofilovga fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT kondratevva fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT lentiv fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT lyapinvg fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT stolyarovoi fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT trzaskawh fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT tsimbalfa fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT tulinata fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT valievff fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT villalobosbaillieo fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice
AT vinogradovli fastpretriggerelectronicsoft0centralitymcpbasedstartdetectorforalice