Cargando…
A Prototype Fast Multiplicity Discriminator for ALICE L0 Trigger
The design details and test results of a prototype Multiplicity Discriminator (MD) for the ALICE L0 Trigger electronics are presented. The MD design is aimed at the earliest trigger decision founded on a fast multiplicity signal cut, in both options for the ALICE centrality detector: Micro Channel P...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2001-005.217 http://cds.cern.ch/record/522050 |
Sumario: | The design details and test results of a prototype Multiplicity Discriminator (MD) for the ALICE L0 Trigger electronics are presented. The MD design is aimed at the earliest trigger decision founded on a fast multiplicity signal cut, in both options for the ALICE centrality detector: Micro Channel Plates or Cherenkov counters. The MD accepts detector signals with an amplitude range of plus-minus 2.5 V, base duration of 1.8 ns and rise time of 300-400 ps. The digitally controlled threshold settings give an accuracy better than 0.4% at the maximum amplitude of the accepted pulses. The MD internal latency of 15 ns allows for a decision every LHC bunch crossing period, even for the 40 MHz of p-p collisions. |
---|