Simultaneously non-linear energy calibration of CMS calorimeters for single pions and electrons

CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single electrons from 5 to 500 GeV. The analysis of the simulated data sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Damgov, J., Genchev, V., Mavrodiev, S.C.
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/522584
Descripción
Sumario:CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single electrons from 5 to 500 GeV. The analysis of the simulated data shows that standard calibration using just sampling coefficients for calorimeter parts with different sampling ratio gives nonlinear calorimeter response. Non-linear calibration technique was applied simultaneously for pion and electron beams which is preparation for jets energy reconstruction. It improve calorimeter energy resolution for pions and restore the calorimeter linearity.