High-accuracy mass determination of neutron-rich rubidium and strontiumiIsotopes

The penning-trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of $^{88,89,90m,91,92,93,94}$Rb and $^{91- 95}$Sr. Using a resolving power of R $\!\scriptstyle\approx$1 million a mass accuracy of typically 10 keV was achi...

Descripción completa

Detalles Bibliográficos
Autores principales: Raimbault-Hartmann, H, Audi, G, Beck, D, Bollen, G, De Saint-Simon, M, Kluge, H J, König, M, Moore, R B, Schwarz, S, Savard, G, Szerypo, J
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0375-9474(02)00863-1
http://cds.cern.ch/record/524027
Descripción
Sumario:The penning-trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of $^{88,89,90m,91,92,93,94}$Rb and $^{91- 95}$Sr. Using a resolving power of R $\!\scriptstyle\approx$1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in the general mass adjustment.