A Purity Monitoring System for the H1 Liquid Argon Calorimeter
The ionization probes used for monitoring the liquid argon purity in the H1 calorimeter are described and results of their operation in tests at CERN and during the period 1992 to the end of 1998 at HERA are given. The high sensitivity of the charge measurements leads to refined charge collection mo...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(02)00973-7 http://cds.cern.ch/record/527599 |
_version_ | 1780897941035155456 |
---|---|
author | Barrelet, E |
author_facet | Barrelet, E |
author_sort | Barrelet, E |
collection | CERN |
description | The ionization probes used for monitoring the liquid argon purity in the H1 calorimeter are described and results of their operation in tests at CERN and during the period 1992 to the end of 1998 at HERA are given. The high sensitivity of the charge measurements leads to refined charge collection models, and to the observation of a variation of the ionization yield of our electron sources with temperature. |
id | cern-527599 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5275992019-09-30T06:29:59Zdoi:10.1016/S0168-9002(02)00973-7http://cds.cern.ch/record/527599engBarrelet, EA Purity Monitoring System for the H1 Liquid Argon CalorimeterDetectors and Experimental TechniquesThe ionization probes used for monitoring the liquid argon purity in the H1 calorimeter are described and results of their operation in tests at CERN and during the period 1992 to the end of 1998 at HERA are given. The high sensitivity of the charge measurements leads to refined charge collection models, and to the observation of a variation of the ionization yield of our electron sources with temperature.hep-ex/0111066DESY-2001-188DESY-01-188oai:cds.cern.ch:5275992001-11-20 |
spellingShingle | Detectors and Experimental Techniques Barrelet, E A Purity Monitoring System for the H1 Liquid Argon Calorimeter |
title | A Purity Monitoring System for the H1 Liquid Argon Calorimeter |
title_full | A Purity Monitoring System for the H1 Liquid Argon Calorimeter |
title_fullStr | A Purity Monitoring System for the H1 Liquid Argon Calorimeter |
title_full_unstemmed | A Purity Monitoring System for the H1 Liquid Argon Calorimeter |
title_short | A Purity Monitoring System for the H1 Liquid Argon Calorimeter |
title_sort | purity monitoring system for the h1 liquid argon calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(02)00973-7 http://cds.cern.ch/record/527599 |
work_keys_str_mv | AT barrelete apuritymonitoringsystemfortheh1liquidargoncalorimeter AT barrelete puritymonitoringsystemfortheh1liquidargoncalorimeter |