Cargando…
A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
A low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. The pressu...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2003.10.095 http://cds.cern.ch/record/537152 |
_version_ | 1780898239336153088 |
---|---|
author | Alexopoulos, T Avramidou, R Dris, M Filippas-Tassos, A Gazis, E N Katsoufis, E C Maltezos, S Savva, Panagiota S Stavropoulos, G D Tsipolitis, G |
author_facet | Alexopoulos, T Avramidou, R Dris, M Filippas-Tassos, A Gazis, E N Katsoufis, E C Maltezos, S Savva, Panagiota S Stavropoulos, G D Tsipolitis, G |
author_sort | Alexopoulos, T |
collection | CERN |
description | A low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. The pressure drop of each one of the MDT is measured, within a typical time interval of 48 hours, via a differential manometer comparing with the pressure of a gas tight reference tube. The precision of the method implemented is based on the system temperature homogeneity, with accuracy of ÄT = 0.3 oC. For this reason, two thermally isolated boxes are used testing 50 tubes each of them, to achieve high degree of temperature uniformity and stability. After measuring several thousands of the MDTs, the developed system is confirmed to be appropriate within the specifications for testing the MDTs during the mass production. |
id | cern-537152 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5371522019-09-30T06:29:59Zdoi:10.1016/j.nima.2003.10.095http://cds.cern.ch/record/537152engAlexopoulos, TAvramidou, RDris, MFilippas-Tassos, AGazis, E NKatsoufis, E CMaltezos, SSavva, Panagiota SStavropoulos, G DTsipolitis, GA Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift TubesDetectors and Experimental TechniquesA low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. The pressure drop of each one of the MDT is measured, within a typical time interval of 48 hours, via a differential manometer comparing with the pressure of a gas tight reference tube. The precision of the method implemented is based on the system temperature homogeneity, with accuracy of ÄT = 0.3 oC. For this reason, two thermally isolated boxes are used testing 50 tubes each of them, to achieve high degree of temperature uniformity and stability. After measuring several thousands of the MDTs, the developed system is confirmed to be appropriate within the specifications for testing the MDTs during the mass production.SN-ATLAS-2002-016ATL-COM-MUON-2001-024oai:cds.cern.ch:5371522001-10-20 |
spellingShingle | Detectors and Experimental Techniques Alexopoulos, T Avramidou, R Dris, M Filippas-Tassos, A Gazis, E N Katsoufis, E C Maltezos, S Savva, Panagiota S Stavropoulos, G D Tsipolitis, G A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes |
title | A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes |
title_full | A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes |
title_fullStr | A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes |
title_full_unstemmed | A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes |
title_short | A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes |
title_sort | gas leak rate measurement system for the atlas muon bis-monitored drift tubes |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2003.10.095 http://cds.cern.ch/record/537152 |
work_keys_str_mv | AT alexopoulost agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT avramidour agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT drism agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT filippastassosa agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT gazisen agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT katsoufisec agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT maltezoss agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT savvapanagiotas agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT stavropoulosgd agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT tsipolitisg agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT alexopoulost gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT avramidour gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT drism gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT filippastassosa gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT gazisen gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT katsoufisec gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT maltezoss gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT savvapanagiotas gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT stavropoulosgd gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes AT tsipolitisg gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes |