Cargando…

A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes

A low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. The pressu...

Descripción completa

Detalles Bibliográficos
Autores principales: Alexopoulos, T, Avramidou, R, Dris, M, Filippas-Tassos, A, Gazis, E N, Katsoufis, E C, Maltezos, S, Savva, Panagiota S, Stavropoulos, G D, Tsipolitis, G
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2003.10.095
http://cds.cern.ch/record/537152
_version_ 1780898239336153088
author Alexopoulos, T
Avramidou, R
Dris, M
Filippas-Tassos, A
Gazis, E N
Katsoufis, E C
Maltezos, S
Savva, Panagiota S
Stavropoulos, G D
Tsipolitis, G
author_facet Alexopoulos, T
Avramidou, R
Dris, M
Filippas-Tassos, A
Gazis, E N
Katsoufis, E C
Maltezos, S
Savva, Panagiota S
Stavropoulos, G D
Tsipolitis, G
author_sort Alexopoulos, T
collection CERN
description A low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. The pressure drop of each one of the MDT is measured, within a typical time interval of 48 hours, via a differential manometer comparing with the pressure of a gas tight reference tube. The precision of the method implemented is based on the system temperature homogeneity, with accuracy of ÄT = 0.3 oC. For this reason, two thermally isolated boxes are used testing 50 tubes each of them, to achieve high degree of temperature uniformity and stability. After measuring several thousands of the MDTs, the developed system is confirmed to be appropriate within the specifications for testing the MDTs during the mass production.
id cern-537152
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5371522019-09-30T06:29:59Zdoi:10.1016/j.nima.2003.10.095http://cds.cern.ch/record/537152engAlexopoulos, TAvramidou, RDris, MFilippas-Tassos, AGazis, E NKatsoufis, E CMaltezos, SSavva, Panagiota SStavropoulos, G DTsipolitis, GA Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift TubesDetectors and Experimental TechniquesA low-cost, reliable and precise system developed for the gas leak rate measurement of the BIS-Monitored Drift Tubes (MDTs) for the ATLAS Muon Spectrometer is presented. In order to meet the BIS-MDT mass production rate, a total number of 100 tubes are tested simultaneously in this setup. The pressure drop of each one of the MDT is measured, within a typical time interval of 48 hours, via a differential manometer comparing with the pressure of a gas tight reference tube. The precision of the method implemented is based on the system temperature homogeneity, with accuracy of ÄT = 0.3 oC. For this reason, two thermally isolated boxes are used testing 50 tubes each of them, to achieve high degree of temperature uniformity and stability. After measuring several thousands of the MDTs, the developed system is confirmed to be appropriate within the specifications for testing the MDTs during the mass production.SN-ATLAS-2002-016ATL-COM-MUON-2001-024oai:cds.cern.ch:5371522001-10-20
spellingShingle Detectors and Experimental Techniques
Alexopoulos, T
Avramidou, R
Dris, M
Filippas-Tassos, A
Gazis, E N
Katsoufis, E C
Maltezos, S
Savva, Panagiota S
Stavropoulos, G D
Tsipolitis, G
A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
title A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
title_full A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
title_fullStr A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
title_full_unstemmed A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
title_short A Gas Leak Rate Measurement System for the ATLAS MUON BIS-Monitored Drift Tubes
title_sort gas leak rate measurement system for the atlas muon bis-monitored drift tubes
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2003.10.095
http://cds.cern.ch/record/537152
work_keys_str_mv AT alexopoulost agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT avramidour agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT drism agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT filippastassosa agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT gazisen agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT katsoufisec agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT maltezoss agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT savvapanagiotas agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT stavropoulosgd agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT tsipolitisg agasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT alexopoulost gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT avramidour gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT drism gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT filippastassosa gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT gazisen gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT katsoufisec gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT maltezoss gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT savvapanagiotas gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT stavropoulosgd gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes
AT tsipolitisg gasleakratemeasurementsystemfortheatlasmuonbismonitoreddrifttubes