Cargando…
In-trap conversion electron spectroscopy
The Penning trap REXTRAP at ISOLDE was used to test the feasibility of in-trap conversion electron spectroscopy. The results of simulations, experiments with solid conversion electron sources as well as first on-line and tests with trapped radioactive ions are presented. In addition to obtaining hig...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(02)01368-2 http://cds.cern.ch/record/538541 |
_version_ | 1780898282421092352 |
---|---|
author | Weissman, L Ames, F Äystö, J Forstner, O Reisinger, K Rinta-Antila, S |
author_facet | Weissman, L Ames, F Äystö, J Forstner, O Reisinger, K Rinta-Antila, S |
author_sort | Weissman, L |
collection | CERN |
description | The Penning trap REXTRAP at ISOLDE was used to test the feasibility of in-trap conversion electron spectroscopy. The results of simulations, experiments with solid conversion electron sources as well as first on-line and tests with trapped radioactive ions are presented. In addition to obtaining high-resolution spectroscopic data, the detection of conversion electrons was found to be a useful tool for the diagnostics of the trap operation. The tests proved the feasibility of in-trap spectroscopy but also revealed some potential problems to be addressed in the future. |
id | cern-538541 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-5385412019-09-30T06:29:59Zdoi:10.1016/S0168-9002(02)01368-2http://cds.cern.ch/record/538541engWeissman, LAmes, FÄystö, JForstner, OReisinger, KRinta-Antila, SIn-trap conversion electron spectroscopyAccelerators and Storage RingsThe Penning trap REXTRAP at ISOLDE was used to test the feasibility of in-trap conversion electron spectroscopy. The results of simulations, experiments with solid conversion electron sources as well as first on-line and tests with trapped radioactive ions are presented. In addition to obtaining high-resolution spectroscopic data, the detection of conversion electrons was found to be a useful tool for the diagnostics of the trap operation. The tests proved the feasibility of in-trap spectroscopy but also revealed some potential problems to be addressed in the future.CERN-EP-2002-011oai:cds.cern.ch:5385412002-02-07 |
spellingShingle | Accelerators and Storage Rings Weissman, L Ames, F Äystö, J Forstner, O Reisinger, K Rinta-Antila, S In-trap conversion electron spectroscopy |
title | In-trap conversion electron spectroscopy |
title_full | In-trap conversion electron spectroscopy |
title_fullStr | In-trap conversion electron spectroscopy |
title_full_unstemmed | In-trap conversion electron spectroscopy |
title_short | In-trap conversion electron spectroscopy |
title_sort | in-trap conversion electron spectroscopy |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1016/S0168-9002(02)01368-2 http://cds.cern.ch/record/538541 |
work_keys_str_mv | AT weissmanl intrapconversionelectronspectroscopy AT amesf intrapconversionelectronspectroscopy AT aystoj intrapconversionelectronspectroscopy AT forstnero intrapconversionelectronspectroscopy AT reisingerk intrapconversionelectronspectroscopy AT rintaantilas intrapconversionelectronspectroscopy |