Cargando…
Test beam results for a Shashlik calorimeter with longitudinal segmentation
In the frame of research and development for electromagnetic calorimetry at future e/sup +/e/sup -/ linear colliders, different techniques have been studied to implement longitudinal segmentation in Shashlik calorimeters. Two prototypes with 5*5 cm/sup 2/ lead /scintillator towers and readout by mea...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/23.958736 http://cds.cern.ch/record/559265 |
_version_ | 1780899037462921216 |
---|---|
author | Ask, S Benvenuti, Alberto C Britvich, G I Camporesi, T Checchia, P Fenyuk, A Hedberg, V Lishin, V A Margoni, M Mazzucato, M Obraztsov, V F Paganoni, M Poliakov, V Simonetto, F Terranova, F Vlasov, E |
author_facet | Ask, S Benvenuti, Alberto C Britvich, G I Camporesi, T Checchia, P Fenyuk, A Hedberg, V Lishin, V A Margoni, M Mazzucato, M Obraztsov, V F Paganoni, M Poliakov, V Simonetto, F Terranova, F Vlasov, E |
author_sort | Ask, S |
collection | CERN |
description | In the frame of research and development for electromagnetic calorimetry at future e/sup +/e/sup -/ linear colliders, different techniques have been studied to implement longitudinal segmentation in Shashlik calorimeters. Two prototypes with 5*5 cm/sup 2/ lead /scintillator towers and readout by means of wavelength-shifting fibers have been built. The longitudinal segmentation of the shower is achieved by modifying the front part of the detector. In the first prototype, vacuum photodiodes have been inserted laterally for the first eight X/sub 0/, while in the second prototype a slow scintillator has been used in the first five X/sub 0/. Both of the prototypes have been exposed to beam at CERN. The performance in term of energy resolution, spatial resolution, and e/ pi separation are described. (9 refs). |
id | cern-559265 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5592652019-09-30T06:29:59Zdoi:10.1109/23.958736http://cds.cern.ch/record/559265engAsk, SBenvenuti, Alberto CBritvich, G ICamporesi, TChecchia, PFenyuk, AHedberg, VLishin, V AMargoni, MMazzucato, MObraztsov, V FPaganoni, MPoliakov, VSimonetto, FTerranova, FVlasov, ETest beam results for a Shashlik calorimeter with longitudinal segmentationDetectors and Experimental TechniquesIn the frame of research and development for electromagnetic calorimetry at future e/sup +/e/sup -/ linear colliders, different techniques have been studied to implement longitudinal segmentation in Shashlik calorimeters. Two prototypes with 5*5 cm/sup 2/ lead /scintillator towers and readout by means of wavelength-shifting fibers have been built. The longitudinal segmentation of the shower is achieved by modifying the front part of the detector. In the first prototype, vacuum photodiodes have been inserted laterally for the first eight X/sub 0/, while in the second prototype a slow scintillator has been used in the first five X/sub 0/. Both of the prototypes have been exposed to beam at CERN. The performance in term of energy resolution, spatial resolution, and e/ pi separation are described. (9 refs).oai:cds.cern.ch:5592652001 |
spellingShingle | Detectors and Experimental Techniques Ask, S Benvenuti, Alberto C Britvich, G I Camporesi, T Checchia, P Fenyuk, A Hedberg, V Lishin, V A Margoni, M Mazzucato, M Obraztsov, V F Paganoni, M Poliakov, V Simonetto, F Terranova, F Vlasov, E Test beam results for a Shashlik calorimeter with longitudinal segmentation |
title | Test beam results for a Shashlik calorimeter with longitudinal segmentation |
title_full | Test beam results for a Shashlik calorimeter with longitudinal segmentation |
title_fullStr | Test beam results for a Shashlik calorimeter with longitudinal segmentation |
title_full_unstemmed | Test beam results for a Shashlik calorimeter with longitudinal segmentation |
title_short | Test beam results for a Shashlik calorimeter with longitudinal segmentation |
title_sort | test beam results for a shashlik calorimeter with longitudinal segmentation |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/23.958736 http://cds.cern.ch/record/559265 |
work_keys_str_mv | AT asks testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT benvenutialbertoc testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT britvichgi testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT camporesit testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT checchiap testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT fenyuka testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT hedbergv testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT lishinva testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT margonim testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT mazzucatom testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT obraztsovvf testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT paganonim testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT poliakovv testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT simonettof testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT terranovaf testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation AT vlasove testbeamresultsforashashlikcalorimeterwithlongitudinalsegmentation |