Cargando…
Measurement of proportional counter gas gain
A method of evaluation of proportional counter gas gain from arbitrary current measurements has been developed. It provides absolute value of the gain in range from 1 to 10**8 with moderate current sensitivity and without knowledge of used radioactive source properties. As an example we present depe...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/560366 |
_version_ | 1780899064388255744 |
---|---|
author | Borisov, A Fakhrutdinov, R M Goryachev, V N Kojine, A |
author_facet | Borisov, A Fakhrutdinov, R M Goryachev, V N Kojine, A |
author_sort | Borisov, A |
collection | CERN |
description | A method of evaluation of proportional counter gas gain from arbitrary current measurements has been developed. It provides absolute value of the gain in range from 1 to 10**8 with moderate current sensitivity and without knowledge of used radioactive source properties. As an example we present dependence of the gain versus voltage for drift lubes of ATLAS Muon Spectrometer filled with mixtures Ar-CO//2(93-7) and Ar-N//2-CH//4(91-4-5) at 3 bar absolute pressure. Results are compared with the gain obtained from ADC measurements. 7 Refs. |
id | cern-560366 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-5603662019-09-30T06:29:59Zhttp://cds.cern.ch/record/560366engBorisov, AFakhrutdinov, R MGoryachev, V NKojine, AMeasurement of proportional counter gas gainDetectors and Experimental TechniquesA method of evaluation of proportional counter gas gain from arbitrary current measurements has been developed. It provides absolute value of the gain in range from 1 to 10**8 with moderate current sensitivity and without knowledge of used radioactive source properties. As an example we present dependence of the gain versus voltage for drift lubes of ATLAS Muon Spectrometer filled with mixtures Ar-CO//2(93-7) and Ar-N//2-CH//4(91-4-5) at 3 bar absolute pressure. Results are compared with the gain obtained from ADC measurements. 7 Refs.oai:cds.cern.ch:5603662000 |
spellingShingle | Detectors and Experimental Techniques Borisov, A Fakhrutdinov, R M Goryachev, V N Kojine, A Measurement of proportional counter gas gain |
title | Measurement of proportional counter gas gain |
title_full | Measurement of proportional counter gas gain |
title_fullStr | Measurement of proportional counter gas gain |
title_full_unstemmed | Measurement of proportional counter gas gain |
title_short | Measurement of proportional counter gas gain |
title_sort | measurement of proportional counter gas gain |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/560366 |
work_keys_str_mv | AT borisova measurementofproportionalcountergasgain AT fakhrutdinovrm measurementofproportionalcountergasgain AT goryachevvn measurementofproportionalcountergasgain AT kojinea measurementofproportionalcountergasgain |