Improvement of energy resolution in time-of-flight method for high energy neutron measurement

In the time-of-flight measurement of high energy neutrons, the time resolution is often required to be as good as possible. For improvement of the energy resolution, the time-of-flight study was made by the use of Li (p, n) reaction at forward angles. Two types of detectors were tested. One was a li...

Descripción completa

Detalles Bibliográficos
Autores principales: Shigyo, N, Iwamoto, Y, Satoh, D, Kitsuki, H, Ishibashi, K, Numajiri, M
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/560428
_version_ 1780899074565734400
author Shigyo, N
Iwamoto, Y
Satoh, D
Kitsuki, H
Ishibashi, K
Numajiri, M
author_facet Shigyo, N
Iwamoto, Y
Satoh, D
Kitsuki, H
Ishibashi, K
Numajiri, M
author_sort Shigyo, N
collection CERN
description In the time-of-flight measurement of high energy neutrons, the time resolution is often required to be as good as possible. For improvement of the energy resolution, the time-of-flight study was made by the use of Li (p, n) reaction at forward angles. Two types of detectors were tested. One was a liquid organic scintillator NE-213 5 inches (127 mm) in diameter and 127 mm thick connected with three Hamamatsu H2431 photomultipliers 2 inches (51 mm) in diameter. The other was NE-213 of the same size with a Hamamatsu R1250 127 mm in diameter. The experiment was made at pi2 beam line of 12 GeV proton synchrotron in High Energy Accelerator Research Organization (KEK). The incident proton energy was 800 MeV, and the flight path was 5 m. Two neutron detectors were set at 0 and 5 degrees, respectively. The time resolutions for prompt gamma rays were 0.5 ns for NE-213 with three H2431s and 1.0 ns for NE-213 with R1250. The energy resolutions for 800 MeV neutrons were derived from these values were 70 and 100 MeV, respectively. 12 Refs.
id cern-560428
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-5604282019-09-30T06:29:59Zhttp://cds.cern.ch/record/560428engShigyo, NIwamoto, YSatoh, DKitsuki, HIshibashi, KNumajiri, MImprovement of energy resolution in time-of-flight method for high energy neutron measurementDetectors and Experimental TechniquesIn the time-of-flight measurement of high energy neutrons, the time resolution is often required to be as good as possible. For improvement of the energy resolution, the time-of-flight study was made by the use of Li (p, n) reaction at forward angles. Two types of detectors were tested. One was a liquid organic scintillator NE-213 5 inches (127 mm) in diameter and 127 mm thick connected with three Hamamatsu H2431 photomultipliers 2 inches (51 mm) in diameter. The other was NE-213 of the same size with a Hamamatsu R1250 127 mm in diameter. The experiment was made at pi2 beam line of 12 GeV proton synchrotron in High Energy Accelerator Research Organization (KEK). The incident proton energy was 800 MeV, and the flight path was 5 m. Two neutron detectors were set at 0 and 5 degrees, respectively. The time resolutions for prompt gamma rays were 0.5 ns for NE-213 with three H2431s and 1.0 ns for NE-213 with R1250. The energy resolutions for 800 MeV neutrons were derived from these values were 70 and 100 MeV, respectively. 12 Refs.oai:cds.cern.ch:5604282000
spellingShingle Detectors and Experimental Techniques
Shigyo, N
Iwamoto, Y
Satoh, D
Kitsuki, H
Ishibashi, K
Numajiri, M
Improvement of energy resolution in time-of-flight method for high energy neutron measurement
title Improvement of energy resolution in time-of-flight method for high energy neutron measurement
title_full Improvement of energy resolution in time-of-flight method for high energy neutron measurement
title_fullStr Improvement of energy resolution in time-of-flight method for high energy neutron measurement
title_full_unstemmed Improvement of energy resolution in time-of-flight method for high energy neutron measurement
title_short Improvement of energy resolution in time-of-flight method for high energy neutron measurement
title_sort improvement of energy resolution in time-of-flight method for high energy neutron measurement
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/560428
work_keys_str_mv AT shigyon improvementofenergyresolutionintimeofflightmethodforhighenergyneutronmeasurement
AT iwamotoy improvementofenergyresolutionintimeofflightmethodforhighenergyneutronmeasurement
AT satohd improvementofenergyresolutionintimeofflightmethodforhighenergyneutronmeasurement
AT kitsukih improvementofenergyresolutionintimeofflightmethodforhighenergyneutronmeasurement
AT ishibashik improvementofenergyresolutionintimeofflightmethodforhighenergyneutronmeasurement
AT numajirim improvementofenergyresolutionintimeofflightmethodforhighenergyneutronmeasurement