Thermal Performance of the LHC Short Straight Section Cryostat

The LHC Short Straight Section (SSS) cryostat houses and thermally protects in vacuum the cold mass which contains a twin-aperture superconducting quadrupole magnet and superconducting corrector magnets operating at 1.9 K in superfluid helium. In addition to mechanical requirements, the cryostat is...

Descripción completa

Detalles Bibliográficos
Autores principales: Bergot, J B, Bourcey, N, Nielsen, L, Parma, Vittorio, Rohmig, P, Roy, E
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/566833
_version_ 1780899174236028928
author Bergot, J B
Bourcey, N
Nielsen, L
Parma, Vittorio
Rohmig, P
Roy, E
author_facet Bergot, J B
Bourcey, N
Nielsen, L
Parma, Vittorio
Rohmig, P
Roy, E
author_sort Bergot, J B
collection CERN
description The LHC Short Straight Section (SSS) cryostat houses and thermally protects in vacuum the cold mass which contains a twin-aperture superconducting quadrupole magnet and superconducting corrector magnets operating at 1.9 K in superfluid helium. In addition to mechanical requirements, the cryostat is designed to minimize the heat in-leak from the ambient temperature to the cold mass. Mechanical components linking the cold mass to the vacuum vessel such as support posts and an insulation vacuum barrier are designed to have minimum heat conductivity with efficient thermalisations for heat interception. Heat in-leak by radiation is reduced by employing multilayer insulation wrapped around the cold mass and an actively cooled aluminium thermal shield. The recent commissioning and operation of two SSS prototypes in the LHC Test String 2 have given a first experimental validation of the thermal performance of the SSS cryostat in nominal operating conditions. Temperature sensors mounted in critical locations provide a temperature mapping which allows a crosscheck with the calculated temperature values and thermal performance. Moreover the measurements allowed a validation of the efficiency of the employed thermalisations. This paper presents the experimental results for the thermal performance of cryostat components and gives a first comparison with the design values.
id cern-566833
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-5668332023-05-31T13:24:13Zhttp://cds.cern.ch/record/566833engBergot, J BBourcey, NNielsen, LParma, VittorioRohmig, PRoy, EThermal Performance of the LHC Short Straight Section CryostatAccelerators and Storage RingsThe LHC Short Straight Section (SSS) cryostat houses and thermally protects in vacuum the cold mass which contains a twin-aperture superconducting quadrupole magnet and superconducting corrector magnets operating at 1.9 K in superfluid helium. In addition to mechanical requirements, the cryostat is designed to minimize the heat in-leak from the ambient temperature to the cold mass. Mechanical components linking the cold mass to the vacuum vessel such as support posts and an insulation vacuum barrier are designed to have minimum heat conductivity with efficient thermalisations for heat interception. Heat in-leak by radiation is reduced by employing multilayer insulation wrapped around the cold mass and an actively cooled aluminium thermal shield. The recent commissioning and operation of two SSS prototypes in the LHC Test String 2 have given a first experimental validation of the thermal performance of the SSS cryostat in nominal operating conditions. Temperature sensors mounted in critical locations provide a temperature mapping which allows a crosscheck with the calculated temperature values and thermal performance. Moreover the measurements allowed a validation of the efficiency of the employed thermalisations. This paper presents the experimental results for the thermal performance of cryostat components and gives a first comparison with the design values.LHC-Project-Report-571CERN-LHC-Project-Report-571oai:cds.cern.ch:5668332002-07-02
spellingShingle Accelerators and Storage Rings
Bergot, J B
Bourcey, N
Nielsen, L
Parma, Vittorio
Rohmig, P
Roy, E
Thermal Performance of the LHC Short Straight Section Cryostat
title Thermal Performance of the LHC Short Straight Section Cryostat
title_full Thermal Performance of the LHC Short Straight Section Cryostat
title_fullStr Thermal Performance of the LHC Short Straight Section Cryostat
title_full_unstemmed Thermal Performance of the LHC Short Straight Section Cryostat
title_short Thermal Performance of the LHC Short Straight Section Cryostat
title_sort thermal performance of the lhc short straight section cryostat
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/566833
work_keys_str_mv AT bergotjb thermalperformanceofthelhcshortstraightsectioncryostat
AT bourceyn thermalperformanceofthelhcshortstraightsectioncryostat
AT nielsenl thermalperformanceofthelhcshortstraightsectioncryostat
AT parmavittorio thermalperformanceofthelhcshortstraightsectioncryostat
AT rohmigp thermalperformanceofthelhcshortstraightsectioncryostat
AT roye thermalperformanceofthelhcshortstraightsectioncryostat