Cargando…

Silicon sensors for the CMS preshower detector

This paper is a summary of a research and development programme, conducted during the past 3 years on the CMS Preshower silicon sensors to define the specifications. The main purpose was to study the radiation hardness of these devices resulting from the specific design (metal lines wider than the p...

Descripción completa

Detalles Bibliográficos
Autores principales: Bloch, P, Chang, Y H, Chen, A E, Cheremuhin, A E, Egorov, N, Go, A, Golubkov, S A, Golutvin, I A, Hou, S R, Konjkov, K, Kozlov, Y, Kyriakis, A, Lin, W T, Loukas, D, Markou, A, Mousa, J, Peisert, Anna, Sidorov, A, Tsoi, E, Zamiatin, N I, Zubarev, E V
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(01)00900-7
http://cds.cern.ch/record/567327
_version_ 1780899204819845120
author Bloch, P
Chang, Y H
Chen, A E
Cheremuhin, A E
Egorov, N
Go, A
Golubkov, S A
Golutvin, I A
Hou, S R
Konjkov, K
Kozlov, Y
Kyriakis, A
Lin, W T
Loukas, D
Markou, A
Mousa, J
Peisert, Anna
Sidorov, A
Tsoi, E
Zamiatin, N I
Zubarev, E V
author_facet Bloch, P
Chang, Y H
Chen, A E
Cheremuhin, A E
Egorov, N
Go, A
Golubkov, S A
Golutvin, I A
Hou, S R
Konjkov, K
Kozlov, Y
Kyriakis, A
Lin, W T
Loukas, D
Markou, A
Mousa, J
Peisert, Anna
Sidorov, A
Tsoi, E
Zamiatin, N I
Zubarev, E V
author_sort Bloch, P
collection CERN
description This paper is a summary of a research and development programme, conducted during the past 3 years on the CMS Preshower silicon sensors to define the specifications. The main purpose was to study the radiation hardness of these devices resulting from the specific design (metal lines wider than the p/sup +/ implants) and the production technology, a deep n/sup +/ layer on the ohmic side. An acceptable noise and a uniform charge collection were guaranteed by an appropriate choice of the interstrip region width. About 65 sensors, of different designs and produced by six manufacturers, were irradiated with neutrons and protons and thoroughly tested before and after irradiation. The results of the tests and the final specifications are presented. (18 refs).
id cern-567327
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-5673272019-09-30T06:29:59Zdoi:10.1016/S0168-9002(01)00900-7http://cds.cern.ch/record/567327engBloch, PChang, Y HChen, A ECheremuhin, A EEgorov, NGo, AGolubkov, S AGolutvin, I AHou, S RKonjkov, KKozlov, YKyriakis, ALin, W TLoukas, DMarkou, AMousa, JPeisert, AnnaSidorov, ATsoi, EZamiatin, N IZubarev, E VSilicon sensors for the CMS preshower detectorDetectors and Experimental TechniquesThis paper is a summary of a research and development programme, conducted during the past 3 years on the CMS Preshower silicon sensors to define the specifications. The main purpose was to study the radiation hardness of these devices resulting from the specific design (metal lines wider than the p/sup +/ implants) and the production technology, a deep n/sup +/ layer on the ohmic side. An acceptable noise and a uniform charge collection were guaranteed by an appropriate choice of the interstrip region width. About 65 sensors, of different designs and produced by six manufacturers, were irradiated with neutrons and protons and thoroughly tested before and after irradiation. The results of the tests and the final specifications are presented. (18 refs).oai:cds.cern.ch:5673272002
spellingShingle Detectors and Experimental Techniques
Bloch, P
Chang, Y H
Chen, A E
Cheremuhin, A E
Egorov, N
Go, A
Golubkov, S A
Golutvin, I A
Hou, S R
Konjkov, K
Kozlov, Y
Kyriakis, A
Lin, W T
Loukas, D
Markou, A
Mousa, J
Peisert, Anna
Sidorov, A
Tsoi, E
Zamiatin, N I
Zubarev, E V
Silicon sensors for the CMS preshower detector
title Silicon sensors for the CMS preshower detector
title_full Silicon sensors for the CMS preshower detector
title_fullStr Silicon sensors for the CMS preshower detector
title_full_unstemmed Silicon sensors for the CMS preshower detector
title_short Silicon sensors for the CMS preshower detector
title_sort silicon sensors for the cms preshower detector
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(01)00900-7
http://cds.cern.ch/record/567327
work_keys_str_mv AT blochp siliconsensorsforthecmspreshowerdetector
AT changyh siliconsensorsforthecmspreshowerdetector
AT chenae siliconsensorsforthecmspreshowerdetector
AT cheremuhinae siliconsensorsforthecmspreshowerdetector
AT egorovn siliconsensorsforthecmspreshowerdetector
AT goa siliconsensorsforthecmspreshowerdetector
AT golubkovsa siliconsensorsforthecmspreshowerdetector
AT golutvinia siliconsensorsforthecmspreshowerdetector
AT housr siliconsensorsforthecmspreshowerdetector
AT konjkovk siliconsensorsforthecmspreshowerdetector
AT kozlovy siliconsensorsforthecmspreshowerdetector
AT kyriakisa siliconsensorsforthecmspreshowerdetector
AT linwt siliconsensorsforthecmspreshowerdetector
AT loukasd siliconsensorsforthecmspreshowerdetector
AT markoua siliconsensorsforthecmspreshowerdetector
AT mousaj siliconsensorsforthecmspreshowerdetector
AT peisertanna siliconsensorsforthecmspreshowerdetector
AT sidorova siliconsensorsforthecmspreshowerdetector
AT tsoie siliconsensorsforthecmspreshowerdetector
AT zamiatinni siliconsensorsforthecmspreshowerdetector
AT zubarevev siliconsensorsforthecmspreshowerdetector