In order to produce target-ion sources allowing for a high isotopic resolution in the separator, CERN/ISOLDE (Isotope Separator On Line) has purchased a commercial emittance metre, capable of measuring transverse phase-space emittances for ion-beam intensities down to approximately 1 nA. It was inst...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-583X(02)01922-5 http://cds.cern.ch/record/567352 |
_version_ | 1780899207243104256 |
---|---|
author | Lettry, Jacques Lindroos, M Wenander, F |
author_facet | Lettry, Jacques Lindroos, M Wenander, F |
author_sort | Lettry, Jacques |
collection | CERN |
description | In order to produce target-ion sources allowing for a high isotopic resolution in the separator, CERN/ISOLDE (Isotope Separator On Line) has purchased a commercial emittance metre, capable of measuring transverse phase-space emittances for ion-beam intensities down to approximately 1 nA. It was installed at the ISOLDE off-line separator where targets are tested with respect to material purity and the ion-source efficiencies are determined. Now, also the emittance and brightness are measured for different stable elements. An extensive programme has been launched aiming at a complete survey of the emittance dependence on the various ion-source parameters. Results from the measurements on the different ISOLDE ion-source types, with associated analysis, are presented. |
id | cern-567352 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-5673522021-11-11T09:53:39Zdoi:10.1016/S0168-583X(02)01922-5http://cds.cern.ch/record/567352engLettry, JacquesLindroos, MWenander, FTransverse emittance investigation of the ISOLDE target ion sourcesAccelerators and Storage RingsIn order to produce target-ion sources allowing for a high isotopic resolution in the separator, CERN/ISOLDE (Isotope Separator On Line) has purchased a commercial emittance metre, capable of measuring transverse phase-space emittances for ion-beam intensities down to approximately 1 nA. It was installed at the ISOLDE off-line separator where targets are tested with respect to material purity and the ion-source efficiencies are determined. Now, also the emittance and brightness are measured for different stable elements. An extensive programme has been launched aiming at a complete survey of the emittance dependence on the various ion-source parameters. Results from the measurements on the different ISOLDE ion-source types, with associated analysis, are presented.CERN-PS-2002-045-PPoai:cds.cern.ch:5673522002-07-08 |
spellingShingle | Accelerators and Storage Rings Lettry, Jacques Lindroos, M Wenander, F Transverse emittance investigation of the ISOLDE target ion sources |
title | Transverse emittance investigation of the ISOLDE target ion sources |
title_full | Transverse emittance investigation of the ISOLDE target ion sources |
title_fullStr | Transverse emittance investigation of the ISOLDE target ion sources |
title_full_unstemmed | Transverse emittance investigation of the ISOLDE target ion sources |
title_short | Transverse emittance investigation of the ISOLDE target ion sources |
title_sort | transverse emittance investigation of the isolde target ion sources |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1016/S0168-583X(02)01922-5 http://cds.cern.ch/record/567352 |
work_keys_str_mv | AT lettryjacques transverseemittanceinvestigationoftheisoldetargetionsources AT lindroosm transverseemittanceinvestigationoftheisoldetargetionsources AT wenanderf transverseemittanceinvestigationoftheisoldetargetionsources |