Optimization of the Even Normal Multipole Components in the Main Dipole of the Large Hadron Collider

In this paper we discuss even multipolar components of the Large Hadron Collider dipole in relation to the manufacturing features and target values required by beam dynamics. Due to the two-in-one collar geometry, systematic components are induced by the mutual influence of the two apertures and are...

Descripción completa

Detalles Bibliográficos
Autores principales: Bottura, L, Redaelli, S, Remondino, Vittorio, Sanfilippo, S, Savary, F, Scandale, Walter, Todesco, Ezio
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/569476