Cargando…
Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
An original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/571725 |
_version_ | 1780899258418855936 |
---|---|
author | Di Ciaccio, Lucia Neukermans, L Perrodo, P Zitoun, R |
author_facet | Di Ciaccio, Lucia Neukermans, L Perrodo, P Zitoun, R |
author_sort | Di Ciaccio, Lucia |
collection | CERN |
description | An original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the electrical description of the read-out electronics in the reconstruction of the physics pulses. Results on improvements in the LARG response and in particular on the energy uniformity of the calorimeter are shown. |
id | cern-571725 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5717252019-09-30T06:29:59Zhttp://cds.cern.ch/record/571725engDi Ciaccio, LuciaNeukermans, LPerrodo, PZitoun, RUniformity Of The 2000 Test Beam Module With The New Optimal Filtering CoefficientsDetectors and Experimental TechniquesAn original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the electrical description of the read-out electronics in the reconstruction of the physics pulses. Results on improvements in the LARG response and in particular on the energy uniformity of the calorimeter are shown.ATL-LARG-2001-009oai:cds.cern.ch:5717252001 |
spellingShingle | Detectors and Experimental Techniques Di Ciaccio, Lucia Neukermans, L Perrodo, P Zitoun, R Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients |
title | Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients |
title_full | Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients |
title_fullStr | Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients |
title_full_unstemmed | Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients |
title_short | Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients |
title_sort | uniformity of the 2000 test beam module with the new optimal filtering coefficients |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/571725 |
work_keys_str_mv | AT diciacciolucia uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients AT neukermansl uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients AT perrodop uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients AT zitounr uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients |