Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients

An original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Ciaccio, Lucia, Neukermans, L, Perrodo, P, Zitoun, R
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/571725
_version_ 1780899258418855936
author Di Ciaccio, Lucia
Neukermans, L
Perrodo, P
Zitoun, R
author_facet Di Ciaccio, Lucia
Neukermans, L
Perrodo, P
Zitoun, R
author_sort Di Ciaccio, Lucia
collection CERN
description An original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the electrical description of the read-out electronics in the reconstruction of the physics pulses. Results on improvements in the LARG response and in particular on the energy uniformity of the calorimeter are shown.
id cern-571725
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5717252019-09-30T06:29:59Zhttp://cds.cern.ch/record/571725engDi Ciaccio, LuciaNeukermans, LPerrodo, PZitoun, RUniformity Of The 2000 Test Beam Module With The New Optimal Filtering CoefficientsDetectors and Experimental TechniquesAn original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the electrical description of the read-out electronics in the reconstruction of the physics pulses. Results on improvements in the LARG response and in particular on the energy uniformity of the calorimeter are shown.ATL-LARG-2001-009oai:cds.cern.ch:5717252001
spellingShingle Detectors and Experimental Techniques
Di Ciaccio, Lucia
Neukermans, L
Perrodo, P
Zitoun, R
Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
title Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
title_full Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
title_fullStr Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
title_full_unstemmed Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
title_short Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
title_sort uniformity of the 2000 test beam module with the new optimal filtering coefficients
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/571725
work_keys_str_mv AT diciacciolucia uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients
AT neukermansl uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients
AT perrodop uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients
AT zitounr uniformityofthe2000testbeammodulewiththenewoptimalfilteringcoefficients