Cargando…

B$_{s}$ oscillation at LEP and SLC

Seeing the time dependence and measuring the oscillation frequency, Delta m/sub s/, of B/sub s//sup 0/'-B/sub s//sup 0/ mixing will allow the CKM element V/sub td/ to be determined with four times the accuracy of the current determination, which derives from the measurement of Delta M/sub d/. T...

Descripción completa

Detalles Bibliográficos
Autor principal: Rozen, Y
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0920-5632(02)90017-4
http://cds.cern.ch/record/590140
_version_ 1780899648323452928
author Rozen, Y
author_facet Rozen, Y
author_sort Rozen, Y
collection CERN
description Seeing the time dependence and measuring the oscillation frequency, Delta m/sub s/, of B/sub s//sup 0/'-B/sub s//sup 0/ mixing will allow the CKM element V/sub td/ to be determined with four times the accuracy of the current determination, which derives from the measurement of Delta M/sub d/. The resulting change in accuracy could be decisive in demonstrating that the Wolfenstein parameter which describes CP violation, eta , is non-zero. In the longer term, a precise determination of V/sub td/, together with a measurement of sin 2 beta , will provide the most accurate determination of the Wolfenstein parameters rho and eta , and so complete the determination of the CKM matrix or point to fundamental inconsistencies in this description of quark mixing. (18 refs).
id cern-590140
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-5901402019-09-30T06:29:59Zdoi:10.1016/S0920-5632(02)90017-4http://cds.cern.ch/record/590140engRozen, YB$_{s}$ oscillation at LEP and SLCDetectors and Experimental TechniquesSeeing the time dependence and measuring the oscillation frequency, Delta m/sub s/, of B/sub s//sup 0/'-B/sub s//sup 0/ mixing will allow the CKM element V/sub td/ to be determined with four times the accuracy of the current determination, which derives from the measurement of Delta M/sub d/. The resulting change in accuracy could be decisive in demonstrating that the Wolfenstein parameter which describes CP violation, eta , is non-zero. In the longer term, a precise determination of V/sub td/, together with a measurement of sin 2 beta , will provide the most accurate determination of the Wolfenstein parameters rho and eta , and so complete the determination of the CKM matrix or point to fundamental inconsistencies in this description of quark mixing. (18 refs).oai:cds.cern.ch:5901402002
spellingShingle Detectors and Experimental Techniques
Rozen, Y
B$_{s}$ oscillation at LEP and SLC
title B$_{s}$ oscillation at LEP and SLC
title_full B$_{s}$ oscillation at LEP and SLC
title_fullStr B$_{s}$ oscillation at LEP and SLC
title_full_unstemmed B$_{s}$ oscillation at LEP and SLC
title_short B$_{s}$ oscillation at LEP and SLC
title_sort b$_{s}$ oscillation at lep and slc
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0920-5632(02)90017-4
http://cds.cern.ch/record/590140
work_keys_str_mv AT rozeny bsoscillationatlepandslc