Cargando…
Aging studies of CMS muon chamber prototypes
Aging of CMS muon cathode strip chamber prototypes under sustained irradiation was studied. The tests were performed with three prototypes of different gas seal designs and with three gas mixtures Ar(30%) + CO//2(50%) + CF//4(20%), Ar(30%) + CO//2(70%) and Ar(40%) + CO//2(50%) + CF//4(10%). The CF//...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(02)00400-X http://cds.cern.ch/record/592996 |
_version_ | 1780899711498059776 |
---|---|
author | Ferguson, T Gavrilov, G E Korytov, A V Krivshich, A G Kuznetsova, E Lobachev, E Mitselmakher, G Schipunov, L |
author_facet | Ferguson, T Gavrilov, G E Korytov, A V Krivshich, A G Kuznetsova, E Lobachev, E Mitselmakher, G Schipunov, L |
author_sort | Ferguson, T |
collection | CERN |
description | Aging of CMS muon cathode strip chamber prototypes under sustained irradiation was studied. The tests were performed with three prototypes of different gas seal designs and with three gas mixtures Ar(30%) + CO//2(50%) + CF//4(20%), Ar(30%) + CO//2(70%) and Ar(40%) + CO//2(50%) + CF//4(10%). The CF//4-containing mixtures showed no or little aging for an overall accumulated charge per unit of wire length in excess of 13 C/cm. In comparison, the performance deterioration in the Ar-CO//2 mixture proved to be very dramatic: the gas gain falls by a factor of 2 for each 0.25 C/cm of accumulated charge. |
id | cern-592996 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-5929962019-09-30T06:29:59Zdoi:10.1016/S0168-9002(02)00400-Xhttp://cds.cern.ch/record/592996engFerguson, TGavrilov, G EKorytov, A VKrivshich, A GKuznetsova, ELobachev, EMitselmakher, GSchipunov, LAging studies of CMS muon chamber prototypesDetectors and Experimental TechniquesAging of CMS muon cathode strip chamber prototypes under sustained irradiation was studied. The tests were performed with three prototypes of different gas seal designs and with three gas mixtures Ar(30%) + CO//2(50%) + CF//4(20%), Ar(30%) + CO//2(70%) and Ar(40%) + CO//2(50%) + CF//4(10%). The CF//4-containing mixtures showed no or little aging for an overall accumulated charge per unit of wire length in excess of 13 C/cm. In comparison, the performance deterioration in the Ar-CO//2 mixture proved to be very dramatic: the gas gain falls by a factor of 2 for each 0.25 C/cm of accumulated charge.oai:cds.cern.ch:5929962002 |
spellingShingle | Detectors and Experimental Techniques Ferguson, T Gavrilov, G E Korytov, A V Krivshich, A G Kuznetsova, E Lobachev, E Mitselmakher, G Schipunov, L Aging studies of CMS muon chamber prototypes |
title | Aging studies of CMS muon chamber prototypes |
title_full | Aging studies of CMS muon chamber prototypes |
title_fullStr | Aging studies of CMS muon chamber prototypes |
title_full_unstemmed | Aging studies of CMS muon chamber prototypes |
title_short | Aging studies of CMS muon chamber prototypes |
title_sort | aging studies of cms muon chamber prototypes |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(02)00400-X http://cds.cern.ch/record/592996 |
work_keys_str_mv | AT fergusont agingstudiesofcmsmuonchamberprototypes AT gavrilovge agingstudiesofcmsmuonchamberprototypes AT korytovav agingstudiesofcmsmuonchamberprototypes AT krivshichag agingstudiesofcmsmuonchamberprototypes AT kuznetsovae agingstudiesofcmsmuonchamberprototypes AT lobacheve agingstudiesofcmsmuonchamberprototypes AT mitselmakherg agingstudiesofcmsmuonchamberprototypes AT schipunovl agingstudiesofcmsmuonchamberprototypes |