Cargando…

Aging studies of CMS muon chamber prototypes

Aging of CMS muon cathode strip chamber prototypes under sustained irradiation was studied. The tests were performed with three prototypes of different gas seal designs and with three gas mixtures Ar(30%) + CO//2(50%) + CF//4(20%), Ar(30%) + CO//2(70%) and Ar(40%) + CO//2(50%) + CF//4(10%). The CF//...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferguson, T, Gavrilov, G E, Korytov, A V, Krivshich, A G, Kuznetsova, E, Lobachev, E, Mitselmakher, G, Schipunov, L
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(02)00400-X
http://cds.cern.ch/record/592996
_version_ 1780899711498059776
author Ferguson, T
Gavrilov, G E
Korytov, A V
Krivshich, A G
Kuznetsova, E
Lobachev, E
Mitselmakher, G
Schipunov, L
author_facet Ferguson, T
Gavrilov, G E
Korytov, A V
Krivshich, A G
Kuznetsova, E
Lobachev, E
Mitselmakher, G
Schipunov, L
author_sort Ferguson, T
collection CERN
description Aging of CMS muon cathode strip chamber prototypes under sustained irradiation was studied. The tests were performed with three prototypes of different gas seal designs and with three gas mixtures Ar(30%) + CO//2(50%) + CF//4(20%), Ar(30%) + CO//2(70%) and Ar(40%) + CO//2(50%) + CF//4(10%). The CF//4-containing mixtures showed no or little aging for an overall accumulated charge per unit of wire length in excess of 13 C/cm. In comparison, the performance deterioration in the Ar-CO//2 mixture proved to be very dramatic: the gas gain falls by a factor of 2 for each 0.25 C/cm of accumulated charge.
id cern-592996
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-5929962019-09-30T06:29:59Zdoi:10.1016/S0168-9002(02)00400-Xhttp://cds.cern.ch/record/592996engFerguson, TGavrilov, G EKorytov, A VKrivshich, A GKuznetsova, ELobachev, EMitselmakher, GSchipunov, LAging studies of CMS muon chamber prototypesDetectors and Experimental TechniquesAging of CMS muon cathode strip chamber prototypes under sustained irradiation was studied. The tests were performed with three prototypes of different gas seal designs and with three gas mixtures Ar(30%) + CO//2(50%) + CF//4(20%), Ar(30%) + CO//2(70%) and Ar(40%) + CO//2(50%) + CF//4(10%). The CF//4-containing mixtures showed no or little aging for an overall accumulated charge per unit of wire length in excess of 13 C/cm. In comparison, the performance deterioration in the Ar-CO//2 mixture proved to be very dramatic: the gas gain falls by a factor of 2 for each 0.25 C/cm of accumulated charge.oai:cds.cern.ch:5929962002
spellingShingle Detectors and Experimental Techniques
Ferguson, T
Gavrilov, G E
Korytov, A V
Krivshich, A G
Kuznetsova, E
Lobachev, E
Mitselmakher, G
Schipunov, L
Aging studies of CMS muon chamber prototypes
title Aging studies of CMS muon chamber prototypes
title_full Aging studies of CMS muon chamber prototypes
title_fullStr Aging studies of CMS muon chamber prototypes
title_full_unstemmed Aging studies of CMS muon chamber prototypes
title_short Aging studies of CMS muon chamber prototypes
title_sort aging studies of cms muon chamber prototypes
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(02)00400-X
http://cds.cern.ch/record/592996
work_keys_str_mv AT fergusont agingstudiesofcmsmuonchamberprototypes
AT gavrilovge agingstudiesofcmsmuonchamberprototypes
AT korytovav agingstudiesofcmsmuonchamberprototypes
AT krivshichag agingstudiesofcmsmuonchamberprototypes
AT kuznetsovae agingstudiesofcmsmuonchamberprototypes
AT lobacheve agingstudiesofcmsmuonchamberprototypes
AT mitselmakherg agingstudiesofcmsmuonchamberprototypes
AT schipunovl agingstudiesofcmsmuonchamberprototypes