Cargando…

Diagnostics and monitoring of RPC muon trigger in CMS experiment

Diagnostics and calibration circuits for RPC muon trigger were described. Diagnostics based on continuous monitoring of particular blocks of electronic signal processing and transmission channel and performing periodically dedicated tests were described. Standardized diagnostic devices were introduc...

Descripción completa

Detalles Bibliográficos
Autores principales: Bunskowski, K, Kudla, I G, Nakielski, T, Pietrusinski, M, Pozniak, Krzysztof T, Romaniuk, Ryszard, Wrochna, G, Zabolotny, W M
Lenguaje:pol
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/596693
_version_ 1780899826295111680
author Bunskowski, K
Kudla, I G
Nakielski, T
Pietrusinski, M
Pozniak, Krzysztof T
Romaniuk, Ryszard
Wrochna, G
Zabolotny, W M
author_facet Bunskowski, K
Kudla, I G
Nakielski, T
Pietrusinski, M
Pozniak, Krzysztof T
Romaniuk, Ryszard
Wrochna, G
Zabolotny, W M
author_sort Bunskowski, K
collection CERN
description Diagnostics and calibration circuits for RPC muon trigger were described. Diagnostics based on continuous monitoring of particular blocks of electronic signal processing and transmission channel and performing periodically dedicated tests were described. Standardized diagnostic devices were introduced. The devices were realized in an algorithmic and parametric way using the VHDL language. The solutions were realized in ALTERA programmable matrices. (9 refs).
id cern-596693
institution Organización Europea para la Investigación Nuclear
language pol
publishDate 2002
record_format invenio
spelling cern-5966932019-09-30T06:29:59Zhttp://cds.cern.ch/record/596693polBunskowski, KKudla, I GNakielski, TPietrusinski, MPozniak, Krzysztof TRomaniuk, RyszardWrochna, GZabolotny, W MDiagnostics and monitoring of RPC muon trigger in CMS experimentDetectors and Experimental TechniquesDiagnostics and calibration circuits for RPC muon trigger were described. Diagnostics based on continuous monitoring of particular blocks of electronic signal processing and transmission channel and performing periodically dedicated tests were described. Standardized diagnostic devices were introduced. The devices were realized in an algorithmic and parametric way using the VHDL language. The solutions were realized in ALTERA programmable matrices. (9 refs).oai:cds.cern.ch:5966932002
spellingShingle Detectors and Experimental Techniques
Bunskowski, K
Kudla, I G
Nakielski, T
Pietrusinski, M
Pozniak, Krzysztof T
Romaniuk, Ryszard
Wrochna, G
Zabolotny, W M
Diagnostics and monitoring of RPC muon trigger in CMS experiment
title Diagnostics and monitoring of RPC muon trigger in CMS experiment
title_full Diagnostics and monitoring of RPC muon trigger in CMS experiment
title_fullStr Diagnostics and monitoring of RPC muon trigger in CMS experiment
title_full_unstemmed Diagnostics and monitoring of RPC muon trigger in CMS experiment
title_short Diagnostics and monitoring of RPC muon trigger in CMS experiment
title_sort diagnostics and monitoring of rpc muon trigger in cms experiment
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/596693
work_keys_str_mv AT bunskowskik diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT kudlaig diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT nakielskit diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT pietrusinskim diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT pozniakkrzysztoft diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT romaniukryszard diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT wrochnag diagnosticsandmonitoringofrpcmuontriggerincmsexperiment
AT zabolotnywm diagnosticsandmonitoringofrpcmuontriggerincmsexperiment