Field quality analysis to monitor the industrial series production of the dipole magnets for the Large Hadron Collider
In superconducting accelerator magnets, the field quality is mainly determined by conductor position inside the coil. For the LHC, the dipolar field homogeneity must be assured up to 10-5 of the main field component, imposing strict manufacturing tolerances. Magnetic measurements at room temperature...