New results from an extensive aging test on bakelite Resistive Plate Chambers

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single-gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Carboni, G, Collazuol, Gianmaria, De Capua, Stefano, Domenici, Danilo, Ganis, Gerardo, Messi, Roberto, Passaleva, Giovanni, Santovetti, Emanuele, Veltri, Michele
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0920-5632(03)02275-8
http://cds.cern.ch/record/606424
Descripción
Sumario:We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single-gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOhm to more than 250 MOhm. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm^2 to less than 0.15 kHz/cm^2 is also found.