Cargando…
CNGS beam monitor with the LVD detector
The importance of an adequate CNGS beam monitor at the Gran Sasso Laboratory has been stressed in many papers. Since the number of internal $\nu_\mu$ CC and NC interactions in the various detectors will not allow to collect statistics rapidly, one should also be able to detect the $\nu_\mu$ CC inter...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2003.07.068 http://cds.cern.ch/record/612784 |
_version_ | 1780900259484925952 |
---|---|
author | Aglietta, M Antonioli, P Bari, G Castagnoli, C Fulgione, W Galeotti, P Garbini, M Ghia, P L Giusti, P Kemp, E Malguin, A S Menghetti, H Pesci, A Pless, I A Porta, A Ryasny, V G Ryazhskaya, O G Saavedra, O Sartorelli, G Selvi, M Vigorito, C Votano, L Yakushev, V F Zatsepin, G T Zichichi, A |
author_facet | Aglietta, M Antonioli, P Bari, G Castagnoli, C Fulgione, W Galeotti, P Garbini, M Ghia, P L Giusti, P Kemp, E Malguin, A S Menghetti, H Pesci, A Pless, I A Porta, A Ryasny, V G Ryazhskaya, O G Saavedra, O Sartorelli, G Selvi, M Vigorito, C Votano, L Yakushev, V F Zatsepin, G T Zichichi, A |
author_sort | Aglietta, M |
collection | CERN |
description | The importance of an adequate CNGS beam monitor at the Gran Sasso Laboratory has been stressed in many papers. Since the number of internal $\nu_\mu$ CC and NC interactions in the various detectors will not allow to collect statistics rapidly, one should also be able to detect the $\nu_\mu$ CC interactions in the upstream rock. In this study we have investigated the performances of the LVD detector as a monitor for the CNGS neutrino beam. Thanks to its wide area ($13 \times 11 m^2$ orthogonal to the beam direction) LVD can detect about 120 muons per day originated by $\nu_\mu$ CC interactions in the rock. The LVD total mass is $\sim2 kt$. This allows to get 30 more CNGS events per day as internal $(NC + CC)$ $\nu_\mu$ interactions, for a total of $\sim 150$ events per day. A 3% statistical error can be reached in 7 days. Taking into account the time characteristics of the CNGS beam, the cosmic muon background can be reduced to a negligible level, of the order of 1.5 events per day. |
id | cern-612784 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-6127842019-09-30T06:29:59Zdoi:10.1016/j.nima.2003.07.068http://cds.cern.ch/record/612784engAglietta, MAntonioli, PBari, GCastagnoli, CFulgione, WGaleotti, PGarbini, MGhia, P LGiusti, PKemp, EMalguin, A SMenghetti, HPesci, APless, I APorta, ARyasny, V GRyazhskaya, O GSaavedra, OSartorelli, GSelvi, MVigorito, CVotano, LYakushev, V FZatsepin, G TZichichi, ACNGS beam monitor with the LVD detectorDetectors and Experimental TechniquesThe importance of an adequate CNGS beam monitor at the Gran Sasso Laboratory has been stressed in many papers. Since the number of internal $\nu_\mu$ CC and NC interactions in the various detectors will not allow to collect statistics rapidly, one should also be able to detect the $\nu_\mu$ CC interactions in the upstream rock. In this study we have investigated the performances of the LVD detector as a monitor for the CNGS neutrino beam. Thanks to its wide area ($13 \times 11 m^2$ orthogonal to the beam direction) LVD can detect about 120 muons per day originated by $\nu_\mu$ CC interactions in the rock. The LVD total mass is $\sim2 kt$. This allows to get 30 more CNGS events per day as internal $(NC + CC)$ $\nu_\mu$ interactions, for a total of $\sim 150$ events per day. A 3% statistical error can be reached in 7 days. Taking into account the time characteristics of the CNGS beam, the cosmic muon background can be reduced to a negligible level, of the order of 1.5 events per day.hep-ex/0304018LNGS-EXP-2003-05oai:cds.cern.ch:6127842003-04-11 |
spellingShingle | Detectors and Experimental Techniques Aglietta, M Antonioli, P Bari, G Castagnoli, C Fulgione, W Galeotti, P Garbini, M Ghia, P L Giusti, P Kemp, E Malguin, A S Menghetti, H Pesci, A Pless, I A Porta, A Ryasny, V G Ryazhskaya, O G Saavedra, O Sartorelli, G Selvi, M Vigorito, C Votano, L Yakushev, V F Zatsepin, G T Zichichi, A CNGS beam monitor with the LVD detector |
title | CNGS beam monitor with the LVD detector |
title_full | CNGS beam monitor with the LVD detector |
title_fullStr | CNGS beam monitor with the LVD detector |
title_full_unstemmed | CNGS beam monitor with the LVD detector |
title_short | CNGS beam monitor with the LVD detector |
title_sort | cngs beam monitor with the lvd detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2003.07.068 http://cds.cern.ch/record/612784 |
work_keys_str_mv | AT agliettam cngsbeammonitorwiththelvddetector AT antoniolip cngsbeammonitorwiththelvddetector AT barig cngsbeammonitorwiththelvddetector AT castagnolic cngsbeammonitorwiththelvddetector AT fulgionew cngsbeammonitorwiththelvddetector AT galeottip cngsbeammonitorwiththelvddetector AT garbinim cngsbeammonitorwiththelvddetector AT ghiapl cngsbeammonitorwiththelvddetector AT giustip cngsbeammonitorwiththelvddetector AT kempe cngsbeammonitorwiththelvddetector AT malguinas cngsbeammonitorwiththelvddetector AT menghettih cngsbeammonitorwiththelvddetector AT pescia cngsbeammonitorwiththelvddetector AT plessia cngsbeammonitorwiththelvddetector AT portaa cngsbeammonitorwiththelvddetector AT ryasnyvg cngsbeammonitorwiththelvddetector AT ryazhskayaog cngsbeammonitorwiththelvddetector AT saavedrao cngsbeammonitorwiththelvddetector AT sartorellig cngsbeammonitorwiththelvddetector AT selvim cngsbeammonitorwiththelvddetector AT vigoritoc cngsbeammonitorwiththelvddetector AT votanol cngsbeammonitorwiththelvddetector AT yakushevvf cngsbeammonitorwiththelvddetector AT zatsepingt cngsbeammonitorwiththelvddetector AT zichichia cngsbeammonitorwiththelvddetector |