Cargando…
The NA48 liquid-krypton calorimeter
The NA48 experiment at CERN was primarily designed to measure the value of $\Re(\epsilon '/\epsilon)$, the parameter of direct CP- violation, from two-pion decays in simultaneous $K_{L}^{0}$ and $K_{S}^{0}$ beams produced at two different targets. Data for this measurement were taken from 1997...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(02)01505-X http://cds.cern.ch/record/623239 |
_version_ | 1780900456985264128 |
---|---|
author | Jeitler, Manfred |
author_facet | Jeitler, Manfred |
author_sort | Jeitler, Manfred |
collection | CERN |
description | The NA48 experiment at CERN was primarily designed to measure the value of $\Re(\epsilon '/\epsilon)$, the parameter of direct CP- violation, from two-pion decays in simultaneous $K_{L}^{0}$ and $K_{S}^{0}$ beams produced at two different targets. Data for this measurement were taken from 1997 to 2001. The value obtained from the data taken in 1997-1999 is $\Re(\epsilon '/\epsilon) = (15.3 \pm 2.6) \times 10^{-4}$. The remaining data are being analyzed at present. In 2002 and the following years, rare-decay and CP-violation studies will be made in a high-intensity $K_{S}^{0}$ beam and in simultaneous beams of charged kaons, using basically the same apparatus. Photons from neutral-pion decays are detected by a liquid-krypton calorimeter. For the $\Re(\epsilon '/\epsilon)$ measurement it is very important to suppress the huge background from $K_{L}^{0} \to 3\pi^{0}$ decays, which requires very good spatial, energy and time resolution. |
id | cern-623239 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-6232392019-09-30T06:29:59Zdoi:10.1016/S0168-9002(02)01505-Xhttp://cds.cern.ch/record/623239engJeitler, ManfredThe NA48 liquid-krypton calorimeterDetectors and Experimental TechniquesThe NA48 experiment at CERN was primarily designed to measure the value of $\Re(\epsilon '/\epsilon)$, the parameter of direct CP- violation, from two-pion decays in simultaneous $K_{L}^{0}$ and $K_{S}^{0}$ beams produced at two different targets. Data for this measurement were taken from 1997 to 2001. The value obtained from the data taken in 1997-1999 is $\Re(\epsilon '/\epsilon) = (15.3 \pm 2.6) \times 10^{-4}$. The remaining data are being analyzed at present. In 2002 and the following years, rare-decay and CP-violation studies will be made in a high-intensity $K_{S}^{0}$ beam and in simultaneous beams of charged kaons, using basically the same apparatus. Photons from neutral-pion decays are detected by a liquid-krypton calorimeter. For the $\Re(\epsilon '/\epsilon)$ measurement it is very important to suppress the huge background from $K_{L}^{0} \to 3\pi^{0}$ decays, which requires very good spatial, energy and time resolution.oai:cds.cern.ch:6232392002 |
spellingShingle | Detectors and Experimental Techniques Jeitler, Manfred The NA48 liquid-krypton calorimeter |
title | The NA48 liquid-krypton calorimeter |
title_full | The NA48 liquid-krypton calorimeter |
title_fullStr | The NA48 liquid-krypton calorimeter |
title_full_unstemmed | The NA48 liquid-krypton calorimeter |
title_short | The NA48 liquid-krypton calorimeter |
title_sort | na48 liquid-krypton calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(02)01505-X http://cds.cern.ch/record/623239 |
work_keys_str_mv | AT jeitlermanfred thena48liquidkryptoncalorimeter AT jeitlermanfred na48liquidkryptoncalorimeter |