Cargando…

Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT

Silicon detectors from both standard-silicon and oxygenated-silicon material, which were radiation hard to the dose level expected after ten years of operation in ATLAS, was developed. After irradiation, the detector current decreases throughout the entire annealing period. Results showed that oxyge...

Descripción completa

Detalles Bibliográficos
Autores principales: Johansen, Lars Gimmestad, Andricek, Ladislav, Lutz, Gerhard, Moser, H G, Richter, Rainer H, Robinson, Dave, Stugu, Bjarne
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2002.805341
http://cds.cern.ch/record/623626
_version_ 1780900465838391296
author Johansen, Lars Gimmestad
Andricek, Ladislav
Lutz, Gerhard
Moser, H G
Richter, Rainer H
Robinson, Dave
Stugu, Bjarne
author_facet Johansen, Lars Gimmestad
Andricek, Ladislav
Lutz, Gerhard
Moser, H G
Richter, Rainer H
Robinson, Dave
Stugu, Bjarne
author_sort Johansen, Lars Gimmestad
collection CERN
description Silicon detectors from both standard-silicon and oxygenated-silicon material, which were radiation hard to the dose level expected after ten years of operation in ATLAS, was developed. After irradiation, the detector current decreases throughout the entire annealing period. Results showed that oxygenated detectors were of higher leakage current than standard silicon detectors after irradiation, while the current annealing was similar for two types. (Edited abstract) 6 Refs.
id cern-623626
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6236262019-09-30T06:29:59Zdoi:10.1109/TNS.2002.805341http://cds.cern.ch/record/623626engJohansen, Lars GimmestadAndricek, LadislavLutz, GerhardMoser, H GRichter, Rainer HRobinson, DaveStugu, BjarneRadiation studies of silicon-microstrip detectors for use in ATLAS and SCTDetectors and Experimental TechniquesSilicon detectors from both standard-silicon and oxygenated-silicon material, which were radiation hard to the dose level expected after ten years of operation in ATLAS, was developed. After irradiation, the detector current decreases throughout the entire annealing period. Results showed that oxygenated detectors were of higher leakage current than standard silicon detectors after irradiation, while the current annealing was similar for two types. (Edited abstract) 6 Refs.oai:cds.cern.ch:6236262002
spellingShingle Detectors and Experimental Techniques
Johansen, Lars Gimmestad
Andricek, Ladislav
Lutz, Gerhard
Moser, H G
Richter, Rainer H
Robinson, Dave
Stugu, Bjarne
Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
title Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
title_full Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
title_fullStr Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
title_full_unstemmed Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
title_short Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
title_sort radiation studies of silicon-microstrip detectors for use in atlas and sct
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2002.805341
http://cds.cern.ch/record/623626
work_keys_str_mv AT johansenlarsgimmestad radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct
AT andricekladislav radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct
AT lutzgerhard radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct
AT moserhg radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct
AT richterrainerh radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct
AT robinsondave radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct
AT stugubjarne radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct