Cargando…
Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT
Silicon detectors from both standard-silicon and oxygenated-silicon material, which were radiation hard to the dose level expected after ten years of operation in ATLAS, was developed. After irradiation, the detector current decreases throughout the entire annealing period. Results showed that oxyge...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2002.805341 http://cds.cern.ch/record/623626 |
_version_ | 1780900465838391296 |
---|---|
author | Johansen, Lars Gimmestad Andricek, Ladislav Lutz, Gerhard Moser, H G Richter, Rainer H Robinson, Dave Stugu, Bjarne |
author_facet | Johansen, Lars Gimmestad Andricek, Ladislav Lutz, Gerhard Moser, H G Richter, Rainer H Robinson, Dave Stugu, Bjarne |
author_sort | Johansen, Lars Gimmestad |
collection | CERN |
description | Silicon detectors from both standard-silicon and oxygenated-silicon material, which were radiation hard to the dose level expected after ten years of operation in ATLAS, was developed. After irradiation, the detector current decreases throughout the entire annealing period. Results showed that oxygenated detectors were of higher leakage current than standard silicon detectors after irradiation, while the current annealing was similar for two types. (Edited abstract) 6 Refs. |
id | cern-623626 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-6236262019-09-30T06:29:59Zdoi:10.1109/TNS.2002.805341http://cds.cern.ch/record/623626engJohansen, Lars GimmestadAndricek, LadislavLutz, GerhardMoser, H GRichter, Rainer HRobinson, DaveStugu, BjarneRadiation studies of silicon-microstrip detectors for use in ATLAS and SCTDetectors and Experimental TechniquesSilicon detectors from both standard-silicon and oxygenated-silicon material, which were radiation hard to the dose level expected after ten years of operation in ATLAS, was developed. After irradiation, the detector current decreases throughout the entire annealing period. Results showed that oxygenated detectors were of higher leakage current than standard silicon detectors after irradiation, while the current annealing was similar for two types. (Edited abstract) 6 Refs.oai:cds.cern.ch:6236262002 |
spellingShingle | Detectors and Experimental Techniques Johansen, Lars Gimmestad Andricek, Ladislav Lutz, Gerhard Moser, H G Richter, Rainer H Robinson, Dave Stugu, Bjarne Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT |
title | Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT |
title_full | Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT |
title_fullStr | Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT |
title_full_unstemmed | Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT |
title_short | Radiation studies of silicon-microstrip detectors for use in ATLAS and SCT |
title_sort | radiation studies of silicon-microstrip detectors for use in atlas and sct |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/TNS.2002.805341 http://cds.cern.ch/record/623626 |
work_keys_str_mv | AT johansenlarsgimmestad radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct AT andricekladislav radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct AT lutzgerhard radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct AT moserhg radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct AT richterrainerh radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct AT robinsondave radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct AT stugubjarne radiationstudiesofsiliconmicrostripdetectorsforuseinatlasandsct |