Cargando…

Fast Electron Beam Simulation and Dose Calculation

A flexible multiple source model capable of fast reconstruction of clinical electron beams is presented in this paper. A source model considers multiple virtual sources emulating the effect of accelerator head components. A reference configuration (10 MeV and 10x10 cm2 field size) for a Siemens KD2...

Descripción completa

Detalles Bibliográficos
Autores principales: Trindade, A, Rodrigues, P, Peralta, L, Lopes, M C, Alves, C, Chaves, A
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/626839
_version_ 1780900532911603712
author Trindade, A
Rodrigues, P
Peralta, L
Lopes, M C
Alves, C
Chaves, A
author_facet Trindade, A
Rodrigues, P
Peralta, L
Lopes, M C
Alves, C
Chaves, A
author_sort Trindade, A
collection CERN
description A flexible multiple source model capable of fast reconstruction of clinical electron beams is presented in this paper. A source model considers multiple virtual sources emulating the effect of accelerator head components. A reference configuration (10 MeV and 10x10 cm2 field size) for a Siemens KD2 linear accelerator was simulated in full detail using GEANT3 Monte Carlo code. Our model allows the reconstruction of other beam energies and field sizes as well as other beam configurations for similar accelerators using only the reference beam data. Electron dose calculations were performed with the reconstructed beams in a water phantom and compared with experimental data. An agreement of 1-2% / 1-2 mm was obtained, equivalent to the accuracy of full Monte Carlo accelerator simulation. The source model reduces accelerator simulation CPU time by a factor of 7500 relative to full Monte Carlo approaches. The developed model was then interfaced with DPM, a fast radiation transport Monte Carlo code for dose calculation purposes. Dose distributions and dosimetric parameters calculated in the presence of air gaps using this procedure agrees within 1% / 1 mm with experimental data. The obtained accuracy is significantly improved in comparison with the treatment planning system PLATO currently used in clinical practice. A two order of magnitude efficiency gain, in comparison with full Monte Carlo approach was achieved.
id cern-626839
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-6268392019-09-30T06:29:59Zhttp://cds.cern.ch/record/626839engTrindade, ARodrigues, PPeralta, LLopes, M CAlves, CChaves, AFast Electron Beam Simulation and Dose CalculationHealth Physics and Radiation EffectsA flexible multiple source model capable of fast reconstruction of clinical electron beams is presented in this paper. A source model considers multiple virtual sources emulating the effect of accelerator head components. A reference configuration (10 MeV and 10x10 cm2 field size) for a Siemens KD2 linear accelerator was simulated in full detail using GEANT3 Monte Carlo code. Our model allows the reconstruction of other beam energies and field sizes as well as other beam configurations for similar accelerators using only the reference beam data. Electron dose calculations were performed with the reconstructed beams in a water phantom and compared with experimental data. An agreement of 1-2% / 1-2 mm was obtained, equivalent to the accuracy of full Monte Carlo accelerator simulation. The source model reduces accelerator simulation CPU time by a factor of 7500 relative to full Monte Carlo approaches. The developed model was then interfaced with DPM, a fast radiation transport Monte Carlo code for dose calculation purposes. Dose distributions and dosimetric parameters calculated in the presence of air gaps using this procedure agrees within 1% / 1 mm with experimental data. The obtained accuracy is significantly improved in comparison with the treatment planning system PLATO currently used in clinical practice. A two order of magnitude efficiency gain, in comparison with full Monte Carlo approach was achieved.EXT-2003-049LIP-2003-02oai:cds.cern.ch:6268392003-07-02
spellingShingle Health Physics and Radiation Effects
Trindade, A
Rodrigues, P
Peralta, L
Lopes, M C
Alves, C
Chaves, A
Fast Electron Beam Simulation and Dose Calculation
title Fast Electron Beam Simulation and Dose Calculation
title_full Fast Electron Beam Simulation and Dose Calculation
title_fullStr Fast Electron Beam Simulation and Dose Calculation
title_full_unstemmed Fast Electron Beam Simulation and Dose Calculation
title_short Fast Electron Beam Simulation and Dose Calculation
title_sort fast electron beam simulation and dose calculation
topic Health Physics and Radiation Effects
url http://cds.cern.ch/record/626839
work_keys_str_mv AT trindadea fastelectronbeamsimulationanddosecalculation
AT rodriguesp fastelectronbeamsimulationanddosecalculation
AT peraltal fastelectronbeamsimulationanddosecalculation
AT lopesmc fastelectronbeamsimulationanddosecalculation
AT alvesc fastelectronbeamsimulationanddosecalculation
AT chavesa fastelectronbeamsimulationanddosecalculation