Cargando…
Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL
The operation of super radiation hard prototypes of vacuum fine-mesh phototriodes (VPT) proposed for application in CMS Endcap ECAL at the pseudorapidity of eta greater than or equivalent 2.6 has been investigated in radiation fields up to 50 kGy and neutron fluence of 7 multiplied by 10**1**5neutro...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(03)00795-2 http://cds.cern.ch/record/643245 |
_version_ | 1780900767833522176 |
---|---|
author | Blinnikov, Yu S Gousev, Yu Gninenko, S N Grishin, V Goloubev, V Katchanov, V A Lukianov, V N Levchenko, L A Moroz, F V Mamaeva, G A Postoev, V E Seliverstov, D M Ukhanov, D Yakorev, D |
author_facet | Blinnikov, Yu S Gousev, Yu Gninenko, S N Grishin, V Goloubev, V Katchanov, V A Lukianov, V N Levchenko, L A Moroz, F V Mamaeva, G A Postoev, V E Seliverstov, D M Ukhanov, D Yakorev, D |
author_sort | Blinnikov, Yu S |
collection | CERN |
description | The operation of super radiation hard prototypes of vacuum fine-mesh phototriodes (VPT) proposed for application in CMS Endcap ECAL at the pseudorapidity of eta greater than or equivalent 2.6 has been investigated in radiation fields up to 50 kGy and neutron fluence of 7 multiplied by 10**1**5neutroncm**-**2. It is shown that anode response and the excess noise factor of VPT are independent of given above radiation dose and neutron fluence. The results of VPT gain variation measurements under rapid changes of counting rate are presented for the operation in the pseudorapidity range 1.5 less than approximately equals eta less than approximately equals 3.0. |
id | cern-643245 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-6432452019-09-30T06:29:59Zdoi:10.1016/S0168-9002(03)00795-2http://cds.cern.ch/record/643245engBlinnikov, Yu SGousev, YuGninenko, S NGrishin, VGoloubev, VKatchanov, V ALukianov, V NLevchenko, L AMoroz, F VMamaeva, G APostoev, V ESeliverstov, D MUkhanov, DYakorev, DRadiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECALDetectors and Experimental TechniquesThe operation of super radiation hard prototypes of vacuum fine-mesh phototriodes (VPT) proposed for application in CMS Endcap ECAL at the pseudorapidity of eta greater than or equivalent 2.6 has been investigated in radiation fields up to 50 kGy and neutron fluence of 7 multiplied by 10**1**5neutroncm**-**2. It is shown that anode response and the excess noise factor of VPT are independent of given above radiation dose and neutron fluence. The results of VPT gain variation measurements under rapid changes of counting rate are presented for the operation in the pseudorapidity range 1.5 less than approximately equals eta less than approximately equals 3.0.oai:cds.cern.ch:6432452003 |
spellingShingle | Detectors and Experimental Techniques Blinnikov, Yu S Gousev, Yu Gninenko, S N Grishin, V Goloubev, V Katchanov, V A Lukianov, V N Levchenko, L A Moroz, F V Mamaeva, G A Postoev, V E Seliverstov, D M Ukhanov, D Yakorev, D Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL |
title | Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL |
title_full | Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL |
title_fullStr | Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL |
title_full_unstemmed | Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL |
title_short | Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL |
title_sort | radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at cms ecal |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(03)00795-2 http://cds.cern.ch/record/643245 |
work_keys_str_mv | AT blinnikovyus radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT gousevyu radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT gninenkosn radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT grishinv radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT goloubevv radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT katchanovva radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT lukianovvn radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT levchenkola radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT morozfv radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT mamaevaga radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT postoevve radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT seliverstovdm radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT ukhanovd radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal AT yakorevd radiationhardnessexcessnoisefactorandshorttermgaininstabilityofvacuumphototriodesfortheoperationinpseudorapidityrange15eta30atcmsecal |