A novel current calibration system up to 20 kA

The Large Hadron Collider (LHC) particle accelerator project will require an accuracy of a few parts in 10/sup 6/ in the control of the current to the superconducting magnets. A new infrastructure for calibration is being built at CERN based on DC current reference standards rather than voltage. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Fernqvist, G, Halvarsson, Bjorn, Pett, John G, Pickering, J
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TIM.2003.809914
http://cds.cern.ch/record/643293
_version_ 1780900774123929600
author Fernqvist, G
Halvarsson, Bjorn
Pett, John G
Pickering, J
author_facet Fernqvist, G
Halvarsson, Bjorn
Pett, John G
Pickering, J
author_sort Fernqvist, G
collection CERN
description The Large Hadron Collider (LHC) particle accelerator project will require an accuracy of a few parts in 10/sup 6/ in the control of the current to the superconducting magnets. A new infrastructure for calibration is being built at CERN based on DC current reference standards rather than voltage. The paper describes the rationale, the infrastructure, the transfer methods, and the performance. (4 refs).
id cern-643293
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-6432932019-09-30T06:29:59Zdoi:10.1109/TIM.2003.809914http://cds.cern.ch/record/643293engFernqvist, GHalvarsson, BjornPett, John GPickering, JA novel current calibration system up to 20 kAEngineeringThe Large Hadron Collider (LHC) particle accelerator project will require an accuracy of a few parts in 10/sup 6/ in the control of the current to the superconducting magnets. A new infrastructure for calibration is being built at CERN based on DC current reference standards rather than voltage. The paper describes the rationale, the infrastructure, the transfer methods, and the performance. (4 refs).oai:cds.cern.ch:6432932003
spellingShingle Engineering
Fernqvist, G
Halvarsson, Bjorn
Pett, John G
Pickering, J
A novel current calibration system up to 20 kA
title A novel current calibration system up to 20 kA
title_full A novel current calibration system up to 20 kA
title_fullStr A novel current calibration system up to 20 kA
title_full_unstemmed A novel current calibration system up to 20 kA
title_short A novel current calibration system up to 20 kA
title_sort novel current calibration system up to 20 ka
topic Engineering
url https://dx.doi.org/10.1109/TIM.2003.809914
http://cds.cern.ch/record/643293
work_keys_str_mv AT fernqvistg anovelcurrentcalibrationsystemupto20ka
AT halvarssonbjorn anovelcurrentcalibrationsystemupto20ka
AT pettjohng anovelcurrentcalibrationsystemupto20ka
AT pickeringj anovelcurrentcalibrationsystemupto20ka
AT fernqvistg novelcurrentcalibrationsystemupto20ka
AT halvarssonbjorn novelcurrentcalibrationsystemupto20ka
AT pettjohng novelcurrentcalibrationsystemupto20ka
AT pickeringj novelcurrentcalibrationsystemupto20ka