Cargando…
Design and evaluation of a 10-mA DC current reference standard
A new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TIM.2003.809915 http://cds.cern.ch/record/643294 |
_version_ | 1780900774352519168 |
---|---|
author | Fernqvist, G Hudson, G Pickering, J Power, F |
author_facet | Fernqvist, G Hudson, G Pickering, J Power, F |
author_sort | Fernqvist, G |
collection | CERN |
description | A new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/ per year. The paper describes the requirements and the detailed design and evaluation of the unit. Since similar 10-V standards are commercially available, the paper concentrates on the unique current output capability of this device. (4 refs). |
id | cern-643294 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-6432942019-09-30T06:29:59Zdoi:10.1109/TIM.2003.809915http://cds.cern.ch/record/643294engFernqvist, GHudson, GPickering, JPower, FDesign and evaluation of a 10-mA DC current reference standardEngineeringA new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/ per year. The paper describes the requirements and the detailed design and evaluation of the unit. Since similar 10-V standards are commercially available, the paper concentrates on the unique current output capability of this device. (4 refs).oai:cds.cern.ch:6432942003 |
spellingShingle | Engineering Fernqvist, G Hudson, G Pickering, J Power, F Design and evaluation of a 10-mA DC current reference standard |
title | Design and evaluation of a 10-mA DC current reference standard |
title_full | Design and evaluation of a 10-mA DC current reference standard |
title_fullStr | Design and evaluation of a 10-mA DC current reference standard |
title_full_unstemmed | Design and evaluation of a 10-mA DC current reference standard |
title_short | Design and evaluation of a 10-mA DC current reference standard |
title_sort | design and evaluation of a 10-ma dc current reference standard |
topic | Engineering |
url | https://dx.doi.org/10.1109/TIM.2003.809915 http://cds.cern.ch/record/643294 |
work_keys_str_mv | AT fernqvistg designandevaluationofa10madccurrentreferencestandard AT hudsong designandevaluationofa10madccurrentreferencestandard AT pickeringj designandevaluationofa10madccurrentreferencestandard AT powerf designandevaluationofa10madccurrentreferencestandard |