X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results

Two BIS Module 0 chambers have been scanned at the X-ray tomograph at CERN. In this note the analysis of the x-ray tomograph data is presented. On the basis of the results from the first chamber we implemented improvements in the chamber construction procedure which were verified with the second pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Sampsonidis, D, Petridou, C
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/681592
_version_ 1780901204439597056
author Sampsonidis, D
Petridou, C
author_facet Sampsonidis, D
Petridou, C
author_sort Sampsonidis, D
collection CERN
description Two BIS Module 0 chambers have been scanned at the X-ray tomograph at CERN. In this note the analysis of the x-ray tomograph data is presented. On the basis of the results from the first chamber we implemented improvements in the chamber construction procedure which were verified with the second prototype. The X-ray tomograph results are compared with the QA/QC measurements during the assembly. The geometrical parameters of the chambers determined from the tomograph are in agreement with the design values.
id cern-681592
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6815922019-09-30T06:29:59Zhttp://cds.cern.ch/record/681592engSampsonidis, DPetridou, CX-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the resultsDetectors and Experimental TechniquesTwo BIS Module 0 chambers have been scanned at the X-ray tomograph at CERN. In this note the analysis of the x-ray tomograph data is presented. On the basis of the results from the first chamber we implemented improvements in the chamber construction procedure which were verified with the second prototype. The X-ray tomograph results are compared with the QA/QC measurements during the assembly. The geometrical parameters of the chambers determined from the tomograph are in agreement with the design values.ATL-MUON-2004-008oai:cds.cern.ch:6815922002-01-25
spellingShingle Detectors and Experimental Techniques
Sampsonidis, D
Petridou, C
X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results
title X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results
title_full X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results
title_fullStr X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results
title_full_unstemmed X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results
title_short X-ray Tomograph results from two BIS Module 0 Chambers and improvements of the construction procedure on the basis of the results
title_sort x-ray tomograph results from two bis module 0 chambers and improvements of the construction procedure on the basis of the results
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/681592
work_keys_str_mv AT sampsonidisd xraytomographresultsfromtwobismodule0chambersandimprovementsoftheconstructionprocedureonthebasisoftheresults
AT petridouc xraytomographresultsfromtwobismodule0chambersandimprovementsoftheconstructionprocedureonthebasisoftheresults