Cargando…

Temperature Dependence of MDT Wire Tension

The wire tension of an 80~cm long aluminum drift tube was measured as a function of temperature in the range of 20~$^0$C to 30~$^0$C. The temperature dependence of the wire tension was found to be ( 1.56$\pm$0.025)~g/~$^0$C in good agreement with the expectation of 1.57~g/~$^0$C.

Detalles Bibliográficos
Autor principal: Lagouri, T
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/683695
_version_ 1780901329826217984
author Lagouri, T
author_facet Lagouri, T
author_sort Lagouri, T
collection CERN
description The wire tension of an 80~cm long aluminum drift tube was measured as a function of temperature in the range of 20~$^0$C to 30~$^0$C. The temperature dependence of the wire tension was found to be ( 1.56$\pm$0.025)~g/~$^0$C in good agreement with the expectation of 1.57~g/~$^0$C.
id cern-683695
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-6836952019-09-30T06:29:59Zhttp://cds.cern.ch/record/683695engLagouri, TTemperature Dependence of MDT Wire TensionDetectors and Experimental TechniquesThe wire tension of an 80~cm long aluminum drift tube was measured as a function of temperature in the range of 20~$^0$C to 30~$^0$C. The temperature dependence of the wire tension was found to be ( 1.56$\pm$0.025)~g/~$^0$C in good agreement with the expectation of 1.57~g/~$^0$C.ATL-MUON-98-248oai:cds.cern.ch:6836951998-06-05
spellingShingle Detectors and Experimental Techniques
Lagouri, T
Temperature Dependence of MDT Wire Tension
title Temperature Dependence of MDT Wire Tension
title_full Temperature Dependence of MDT Wire Tension
title_fullStr Temperature Dependence of MDT Wire Tension
title_full_unstemmed Temperature Dependence of MDT Wire Tension
title_short Temperature Dependence of MDT Wire Tension
title_sort temperature dependence of mdt wire tension
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/683695
work_keys_str_mv AT lagourit temperaturedependenceofmdtwiretension