Cargando…
Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data
The Hadronic Endcap modules Zero were tested in the H6 beamline at CERN in April 1998. The response and resolution are evaluated at four impact points for electrons and pions over an energy range of 20 to 180 GeV. The response varies within 1% for electrons. The electron energy resolution is paramet...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/683761 |
_version_ | 1780901343967313920 |
---|---|
author | Dobbs, MA Lefebvre, M O'Neil, D C |
author_facet | Dobbs, MA Lefebvre, M O'Neil, D C |
author_sort | Dobbs, MA |
collection | CERN |
description | The Hadronic Endcap modules Zero were tested in the H6 beamline at CERN in April 1998. The response and resolution are evaluated at four impact points for electrons and pions over an energy range of 20 to 180 GeV. The response varies within 1% for electrons. The electron energy resolution is parameterized as $\frac{\sigma}{E}= \frac{22.0\pm~0.01\%}{\sqrt{E_{0}}} øplus 0.0\pm~0.2\% øplus \frac{0.54\pm~0.02}{E}$ where E$_0$ is expressed in GeV. The pion energy resolution (with pre-subtracted noise) is parameterized as $\frac{\sigma}{E} = \frac{78\pm~2\%}{\sqrt{E_{0}}} øplus 5.0\pm 0.3\% $. |
id | cern-683761 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-6837612019-09-30T06:29:59Zhttp://cds.cern.ch/record/683761engDobbs, MALefebvre, MO'Neil, D CHadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam DataDetectors and Experimental TechniquesThe Hadronic Endcap modules Zero were tested in the H6 beamline at CERN in April 1998. The response and resolution are evaluated at four impact points for electrons and pions over an energy range of 20 to 180 GeV. The response varies within 1% for electrons. The electron energy resolution is parameterized as $\frac{\sigma}{E}= \frac{22.0\pm~0.01\%}{\sqrt{E_{0}}} øplus 0.0\pm~0.2\% øplus \frac{0.54\pm~0.02}{E}$ where E$_0$ is expressed in GeV. The pion energy resolution (with pre-subtracted noise) is parameterized as $\frac{\sigma}{E} = \frac{78\pm~2\%}{\sqrt{E_{0}}} øplus 5.0\pm 0.3\% $.ATL-LARG-99-001HEC-Note-59oai:cds.cern.ch:6837611998-11-23 |
spellingShingle | Detectors and Experimental Techniques Dobbs, MA Lefebvre, M O'Neil, D C Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data |
title | Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data |
title_full | Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data |
title_fullStr | Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data |
title_full_unstemmed | Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data |
title_short | Hadronic Endcap Modules Zero Pion and Electron Energy Scan Analysis from April 1998 Testbeam Data |
title_sort | hadronic endcap modules zero pion and electron energy scan analysis from april 1998 testbeam data |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/683761 |
work_keys_str_mv | AT dobbsma hadronicendcapmoduleszeropionandelectronenergyscananalysisfromapril1998testbeamdata AT lefebvrem hadronicendcapmoduleszeropionandelectronenergyscananalysisfromapril1998testbeamdata AT oneildc hadronicendcapmoduleszeropionandelectronenergyscananalysisfromapril1998testbeamdata |