Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation
The uniformity of the Barrel Module 0 light yield was studied using three sources of information: 180GeV muons impinging the module 0 at 90 degrees, the Cesium source and the light yield calculated using a parametrization for tiles and fibres. The cesium source and muons give an average tile-to-tile...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/683810 |
_version_ | 1780901353729556480 |
---|---|
author | Varanda, M Maio, A Henriques, A |
author_facet | Varanda, M Maio, A Henriques, A |
author_sort | Varanda, M |
collection | CERN |
description | The uniformity of the Barrel Module 0 light yield was studied using three sources of information: 180GeV muons impinging the module 0 at 90 degrees, the Cesium source and the light yield calculated using a parametrization for tiles and fibres. The cesium source and muons give an average tile-to-tile fluctuation of ~+-8% while the maximum fluctuation on the calculated light yield is ~+-5%. The number of photoelectrons per tile size was calculated using the data from the detailed muons scan and a mean number of ~27 photoelectrons per GeV was obtained for the module 0. The uniformity of the response of the module 0 to 180GeV muons and 100GeV pions was studied as a function of the impact point z and eta. The signal response shows a modulation for eta values close to zero which is a consequence of the structural periodicity of the Module 0. The maximum fluctuation on the signal is ~+-(50-60)% of the energy lost by muons in the module 0 for eta=0. The amplitude of the modulation is smaller for pions because the dimensions of the showers makes them less sensitive to the local structure. |
id | cern-683810 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1999 |
record_format | invenio |
spelling | cern-6838102019-09-30T06:29:59Zhttp://cds.cern.ch/record/683810engVaranda, MMaio, AHenriques, AUniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulationDetectors and Experimental TechniquesThe uniformity of the Barrel Module 0 light yield was studied using three sources of information: 180GeV muons impinging the module 0 at 90 degrees, the Cesium source and the light yield calculated using a parametrization for tiles and fibres. The cesium source and muons give an average tile-to-tile fluctuation of ~+-8% while the maximum fluctuation on the calculated light yield is ~+-5%. The number of photoelectrons per tile size was calculated using the data from the detailed muons scan and a mean number of ~27 photoelectrons per GeV was obtained for the module 0. The uniformity of the response of the module 0 to 180GeV muons and 100GeV pions was studied as a function of the impact point z and eta. The signal response shows a modulation for eta values close to zero which is a consequence of the structural periodicity of the Module 0. The maximum fluctuation on the signal is ~+-(50-60)% of the energy lost by muons in the module 0 for eta=0. The amplitude of the modulation is smaller for pions because the dimensions of the showers makes them less sensitive to the local structure.ATL-TILECAL-99-006oai:cds.cern.ch:6838101999-03-11 |
spellingShingle | Detectors and Experimental Techniques Varanda, M Maio, A Henriques, A Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation |
title | Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation |
title_full | Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation |
title_fullStr | Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation |
title_full_unstemmed | Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation |
title_short | Uniformity of the 1996 Barrel Module 0 response to muons and pions: Test Beam data and MC simulation |
title_sort | uniformity of the 1996 barrel module 0 response to muons and pions: test beam data and mc simulation |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/683810 |
work_keys_str_mv | AT varandam uniformityofthe1996barrelmodule0responsetomuonsandpionstestbeamdataandmcsimulation AT maioa uniformityofthe1996barrelmodule0responsetomuonsandpionstestbeamdataandmcsimulation AT henriquesa uniformityofthe1996barrelmodule0responsetomuonsandpionstestbeamdataandmcsimulation |