Cargando…

The quality control of WLS fibres in Pisa

We report on the WLS fibre quality control (QC) procedure developed in Pisa. We have built and put into operation a set up and an analysis procedure which allow a fast and accurate measurement of both light yield and attenuation length of 18 WLS fibres at once. We have measured the overall accuracy...

Descripción completa

Detalles Bibliográficos
Autores principales: Burdin, S, Cavasinni, V, Del Prete, T, Mazzoni, E, Usai, G L, Vasilev, A
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/683905
_version_ 1780901373223632896
author Burdin, S
Cavasinni, V
Del Prete, T
Mazzoni, E
Usai, G L
Vasilev, A
author_facet Burdin, S
Cavasinni, V
Del Prete, T
Mazzoni, E
Usai, G L
Vasilev, A
author_sort Burdin, S
collection CERN
description We report on the WLS fibre quality control (QC) procedure developed in Pisa. We have built and put into operation a set up and an analysis procedure which allow a fast and accurate measurement of both light yield and attenuation length of 18 WLS fibres at once. We have measured the overall accuracy of our method to be 1.5% in the measurement of light yield and 3% of the attenuation length. We report also on the results obtained with this method in the QC of fibres of the first batch recently delivered by Kuraray.
id cern-683905
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-6839052019-09-30T06:29:59Zhttp://cds.cern.ch/record/683905engBurdin, SCavasinni, VDel Prete, TMazzoni, EUsai, G LVasilev, AThe quality control of WLS fibres in PisaDetectors and Experimental TechniquesWe report on the WLS fibre quality control (QC) procedure developed in Pisa. We have built and put into operation a set up and an analysis procedure which allow a fast and accurate measurement of both light yield and attenuation length of 18 WLS fibres at once. We have measured the overall accuracy of our method to be 1.5% in the measurement of light yield and 3% of the attenuation length. We report also on the results obtained with this method in the QC of fibres of the first batch recently delivered by Kuraray.ATL-TILECAL-99-013oai:cds.cern.ch:6839051999-08-06
spellingShingle Detectors and Experimental Techniques
Burdin, S
Cavasinni, V
Del Prete, T
Mazzoni, E
Usai, G L
Vasilev, A
The quality control of WLS fibres in Pisa
title The quality control of WLS fibres in Pisa
title_full The quality control of WLS fibres in Pisa
title_fullStr The quality control of WLS fibres in Pisa
title_full_unstemmed The quality control of WLS fibres in Pisa
title_short The quality control of WLS fibres in Pisa
title_sort quality control of wls fibres in pisa
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/683905
work_keys_str_mv AT burdins thequalitycontrolofwlsfibresinpisa
AT cavasinniv thequalitycontrolofwlsfibresinpisa
AT delpretet thequalitycontrolofwlsfibresinpisa
AT mazzonie thequalitycontrolofwlsfibresinpisa
AT usaigl thequalitycontrolofwlsfibresinpisa
AT vasileva thequalitycontrolofwlsfibresinpisa
AT burdins qualitycontrolofwlsfibresinpisa
AT cavasinniv qualitycontrolofwlsfibresinpisa
AT delpretet qualitycontrolofwlsfibresinpisa
AT mazzonie qualitycontrolofwlsfibresinpisa
AT usaigl qualitycontrolofwlsfibresinpisa
AT vasileva qualitycontrolofwlsfibresinpisa