Cargando…

CSC Performance at High Background Rates

The different factors affecting on the CSC performance at high rate were considered. Their influence on the chamber position resolution and track inefficiency were estimated and measured in the beam test. The full size CSC prototype was tested at the X5 high radiation facility at CERN. The beam test...

Descripción completa

Detalles Bibliográficos
Autores principales: Gordeev, A, Gratchev, V, Kandasamy, A, Nevski, P, Polychronakos, V, O'Connor, P, Tcherniatine, V, Vaniachine, A
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/683947
_version_ 1780901381746458624
author Gordeev, A
Gratchev, V
Kandasamy, A
Nevski, P
Polychronakos, V
O'Connor, P
Tcherniatine, V
Vaniachine, A
author_facet Gordeev, A
Gratchev, V
Kandasamy, A
Nevski, P
Polychronakos, V
O'Connor, P
Tcherniatine, V
Vaniachine, A
author_sort Gordeev, A
collection CERN
description The different factors affecting on the CSC performance at high rate were considered. Their influence on the chamber position resolution and track inefficiency were estimated and measured in the beam test. The full size CSC prototype was tested at the X5 high radiation facility at CERN. The beam test demonstrated position resolution of 70 microns and inefficiency of 24.5 percent in the single layer at the maximum expected background rate. The performance of the CSC muon station as a whole was also estimated on the basis of the measured single layer characteristics. This study shows that for uncorrelated background in the worst case (eta=2.7) the muon station position resolution and track inefficiency are 50 microns and 2 percent respectively.
id cern-683947
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-6839472019-09-30T06:29:59Zhttp://cds.cern.ch/record/683947engGordeev, AGratchev, VKandasamy, ANevski, PPolychronakos, VO'Connor, PTcherniatine, VVaniachine, ACSC Performance at High Background RatesDetectors and Experimental TechniquesThe different factors affecting on the CSC performance at high rate were considered. Their influence on the chamber position resolution and track inefficiency were estimated and measured in the beam test. The full size CSC prototype was tested at the X5 high radiation facility at CERN. The beam test demonstrated position resolution of 70 microns and inefficiency of 24.5 percent in the single layer at the maximum expected background rate. The performance of the CSC muon station as a whole was also estimated on the basis of the measured single layer characteristics. This study shows that for uncorrelated background in the worst case (eta=2.7) the muon station position resolution and track inefficiency are 50 microns and 2 percent respectively.ATL-MUON-2000-005oai:cds.cern.ch:6839471999-10-19
spellingShingle Detectors and Experimental Techniques
Gordeev, A
Gratchev, V
Kandasamy, A
Nevski, P
Polychronakos, V
O'Connor, P
Tcherniatine, V
Vaniachine, A
CSC Performance at High Background Rates
title CSC Performance at High Background Rates
title_full CSC Performance at High Background Rates
title_fullStr CSC Performance at High Background Rates
title_full_unstemmed CSC Performance at High Background Rates
title_short CSC Performance at High Background Rates
title_sort csc performance at high background rates
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/683947
work_keys_str_mv AT gordeeva cscperformanceathighbackgroundrates
AT gratchevv cscperformanceathighbackgroundrates
AT kandasamya cscperformanceathighbackgroundrates
AT nevskip cscperformanceathighbackgroundrates
AT polychronakosv cscperformanceathighbackgroundrates
AT oconnorp cscperformanceathighbackgroundrates
AT tcherniatinev cscperformanceathighbackgroundrates
AT vaniachinea cscperformanceathighbackgroundrates