Light Yield and Uniformity of the Tilecal Barrel Module 0 prototype
The number of photoelectrons per tile size was calculated by two methods, the splitting method, and by the standard technique of photoelectron statistics.The uniformity and the assymetry were studied using both the information provided by radioactive cesium source and the 180 GeV muon data.
Autores principales: | Castillo, V, Fassi, F |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/683995 |