Tests of the presampler electrodes for module 0
The ATLAS presampler will be composed of approximately 90000 printed circuit board electrodes. These electrodes need to be tested to verify that they are whithin the tight thickness and size tolerances required by the module production technique. For the 3-layer anode electrodes a measurement of the...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/684131 |
_version_ | 1780901416964980736 |
---|---|
author | Belymam, A Clément, C Hoummada, A Lund-Jensen, B |
author_facet | Belymam, A Clément, C Hoummada, A Lund-Jensen, B |
author_sort | Belymam, A |
collection | CERN |
description | The ATLAS presampler will be composed of approximately 90000 printed circuit board electrodes. These electrodes need to be tested to verify that they are whithin the tight thickness and size tolerances required by the module production technique. For the 3-layer anode electrodes a measurement of the electrical properties is required. A testbench to automatize these electrical measurements has been developed at KTH. This note presents the results obtained from measurements of thickness, size and electrical properties of the electrodes for the first series produced sectors, "module 0" . The thickness requirements are well fulfiled on 2-layer cathode electrodes. A large fraction of the 3-layer anode electrodes did not meet the thickness specifications. The reasons for this are identified and several improvements of the manufacturing process are proposed. The quality of the contour cutting of the boards is examined on preseries cut by milling and preseries cut by punching. Measurements show that the precision of the milling technique is at the limit of the specifictions. None of the boards produced with the punching technique was found to be outside contour specifications. Electrical test of the boards included in "module 0" showed a behaviour according to the specifications. |
id | cern-684131 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-6841312019-09-30T06:29:59Zhttp://cds.cern.ch/record/684131engBelymam, AClément, CHoummada, ALund-Jensen, BTests of the presampler electrodes for module 0Detectors and Experimental TechniquesThe ATLAS presampler will be composed of approximately 90000 printed circuit board electrodes. These electrodes need to be tested to verify that they are whithin the tight thickness and size tolerances required by the module production technique. For the 3-layer anode electrodes a measurement of the electrical properties is required. A testbench to automatize these electrical measurements has been developed at KTH. This note presents the results obtained from measurements of thickness, size and electrical properties of the electrodes for the first series produced sectors, "module 0" . The thickness requirements are well fulfiled on 2-layer cathode electrodes. A large fraction of the 3-layer anode electrodes did not meet the thickness specifications. The reasons for this are identified and several improvements of the manufacturing process are proposed. The quality of the contour cutting of the boards is examined on preseries cut by milling and preseries cut by punching. Measurements show that the precision of the milling technique is at the limit of the specifictions. None of the boards produced with the punching technique was found to be outside contour specifications. Electrical test of the boards included in "module 0" showed a behaviour according to the specifications.ATL-LARG-2000-008oai:cds.cern.ch:6841312000-10-12 |
spellingShingle | Detectors and Experimental Techniques Belymam, A Clément, C Hoummada, A Lund-Jensen, B Tests of the presampler electrodes for module 0 |
title | Tests of the presampler electrodes for module 0 |
title_full | Tests of the presampler electrodes for module 0 |
title_fullStr | Tests of the presampler electrodes for module 0 |
title_full_unstemmed | Tests of the presampler electrodes for module 0 |
title_short | Tests of the presampler electrodes for module 0 |
title_sort | tests of the presampler electrodes for module 0 |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/684131 |
work_keys_str_mv | AT belymama testsofthepresamplerelectrodesformodule0 AT clementc testsofthepresamplerelectrodesformodule0 AT hoummadaa testsofthepresamplerelectrodesformodule0 AT lundjensenb testsofthepresamplerelectrodesformodule0 |