Calibration of the X-ray Tomograph

An X-ray Tomograph has been constructed to measure the mechanical accuracy of the ATLAS Muon chambers. Here we report on the choice of the measurement scheme, the global calibration procedure and practical aspects of the calibration. We reached for the measurement accuracy a value of 2 /mum systemat...

Descripción completa

Detalles Bibliográficos
Autores principales: Avramidou, R, Berbiers, Julien, Boudineau, C, Drakoulakos, D G, Fabjan, Christian Wolfgang, Grau, S, Gschwendtner, E, Krumshtein, Z, Maugain, J M, Rangod, Stephane, Rieder, H, Rohrbach, F, Sbrissa, E, Schuh, S, Sedykh, E, Sedykh, Yu, Smirnov, Y, Vertogradov, L S, Woudstra, M, Vichou, I
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/684157
_version_ 1780901422131314688
author Avramidou, R
Berbiers, Julien
Boudineau, C
Drakoulakos, D G
Fabjan, Christian Wolfgang
Grau, S
Gschwendtner, E
Krumshtein, Z
Maugain, J M
Rangod, Stephane
Rieder, H
Rohrbach, F
Sbrissa, E
Schuh, S
Sedykh, E
Sedykh, Yu
Smirnov, Y
Vertogradov, L S
Woudstra, M
Vichou, I
author_facet Avramidou, R
Berbiers, Julien
Boudineau, C
Drakoulakos, D G
Fabjan, Christian Wolfgang
Grau, S
Gschwendtner, E
Krumshtein, Z
Maugain, J M
Rangod, Stephane
Rieder, H
Rohrbach, F
Sbrissa, E
Schuh, S
Sedykh, E
Sedykh, Yu
Smirnov, Y
Vertogradov, L S
Woudstra, M
Vichou, I
author_sort Avramidou, R
collection CERN
description An X-ray Tomograph has been constructed to measure the mechanical accuracy of the ATLAS Muon chambers. Here we report on the choice of the measurement scheme, the global calibration procedure and practical aspects of the calibration. We reached for the measurement accuracy a value of 2 /mum systematic and 2 /mum statistical uncertainties in the horizontal and vertical directions. The measurement area is up to 220 cm (horizontal) by 60 cm (vertical).
id cern-684157
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-6841572019-09-30T06:29:59Zhttp://cds.cern.ch/record/684157engAvramidou, RBerbiers, JulienBoudineau, CDrakoulakos, D GFabjan, Christian WolfgangGrau, SGschwendtner, EKrumshtein, ZMaugain, J MRangod, StephaneRieder, HRohrbach, FSbrissa, ESchuh, SSedykh, ESedykh, YuSmirnov, YVertogradov, L SWoudstra, MVichou, ICalibration of the X-ray TomographDetectors and Experimental TechniquesAn X-ray Tomograph has been constructed to measure the mechanical accuracy of the ATLAS Muon chambers. Here we report on the choice of the measurement scheme, the global calibration procedure and practical aspects of the calibration. We reached for the measurement accuracy a value of 2 /mum systematic and 2 /mum statistical uncertainties in the horizontal and vertical directions. The measurement area is up to 220 cm (horizontal) by 60 cm (vertical).ATL-MUON-2001-008oai:cds.cern.ch:6841572000-03-01
spellingShingle Detectors and Experimental Techniques
Avramidou, R
Berbiers, Julien
Boudineau, C
Drakoulakos, D G
Fabjan, Christian Wolfgang
Grau, S
Gschwendtner, E
Krumshtein, Z
Maugain, J M
Rangod, Stephane
Rieder, H
Rohrbach, F
Sbrissa, E
Schuh, S
Sedykh, E
Sedykh, Yu
Smirnov, Y
Vertogradov, L S
Woudstra, M
Vichou, I
Calibration of the X-ray Tomograph
title Calibration of the X-ray Tomograph
title_full Calibration of the X-ray Tomograph
title_fullStr Calibration of the X-ray Tomograph
title_full_unstemmed Calibration of the X-ray Tomograph
title_short Calibration of the X-ray Tomograph
title_sort calibration of the x-ray tomograph
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684157
work_keys_str_mv AT avramidour calibrationofthexraytomograph
AT berbiersjulien calibrationofthexraytomograph
AT boudineauc calibrationofthexraytomograph
AT drakoulakosdg calibrationofthexraytomograph
AT fabjanchristianwolfgang calibrationofthexraytomograph
AT graus calibrationofthexraytomograph
AT gschwendtnere calibrationofthexraytomograph
AT krumshteinz calibrationofthexraytomograph
AT maugainjm calibrationofthexraytomograph
AT rangodstephane calibrationofthexraytomograph
AT riederh calibrationofthexraytomograph
AT rohrbachf calibrationofthexraytomograph
AT sbrissae calibrationofthexraytomograph
AT schuhs calibrationofthexraytomograph
AT sedykhe calibrationofthexraytomograph
AT sedykhyu calibrationofthexraytomograph
AT smirnovy calibrationofthexraytomograph
AT vertogradovls calibrationofthexraytomograph
AT woudstram calibrationofthexraytomograph
AT vichoui calibrationofthexraytomograph