Calibration of a RASNIK system for the ATLAS Muon Spectrometer
We propose a scheme for the absolute calibration of a set of three individual RASNIK elements and of their bench supports. The RASNIK elements consist of three precision cubic blocks carrying the mask, the lens or the CCD. Simulations and measurements on a dedicated bench show that this procedure le...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/684166 |
_version_ | 1780901423854125056 |
---|---|
author | Machefert, F P Guyot, C Schuller, J P Schune, P |
author_facet | Machefert, F P Guyot, C Schuller, J P Schune, P |
author_sort | Machefert, F P |
collection | CERN |
description | We propose a scheme for the absolute calibration of a set of three individual RASNIK elements and of their bench supports. The RASNIK elements consist of three precision cubic blocks carrying the mask, the lens or the CCD. Simulations and measurements on a dedicated bench show that this procedure leads to the required precision on the relevant RASNIK parameters (< 5 microns). These calibrated RASNIK blocks can be used later as references for a fast calibration of the RASNIK sensors to be used in the alignment system of the ATLAS muon spectrometer. |
id | cern-684166 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-6841662019-09-30T06:29:59Zhttp://cds.cern.ch/record/684166engMachefert, F PGuyot, CSchuller, J PSchune, PCalibration of a RASNIK system for the ATLAS Muon SpectrometerDetectors and Experimental TechniquesWe propose a scheme for the absolute calibration of a set of three individual RASNIK elements and of their bench supports. The RASNIK elements consist of three precision cubic blocks carrying the mask, the lens or the CCD. Simulations and measurements on a dedicated bench show that this procedure leads to the required precision on the relevant RASNIK parameters (< 5 microns). These calibrated RASNIK blocks can be used later as references for a fast calibration of the RASNIK sensors to be used in the alignment system of the ATLAS muon spectrometer.ATL-MUON-2001-010oai:cds.cern.ch:6841662001-02-06 |
spellingShingle | Detectors and Experimental Techniques Machefert, F P Guyot, C Schuller, J P Schune, P Calibration of a RASNIK system for the ATLAS Muon Spectrometer |
title | Calibration of a RASNIK system for the ATLAS Muon Spectrometer |
title_full | Calibration of a RASNIK system for the ATLAS Muon Spectrometer |
title_fullStr | Calibration of a RASNIK system for the ATLAS Muon Spectrometer |
title_full_unstemmed | Calibration of a RASNIK system for the ATLAS Muon Spectrometer |
title_short | Calibration of a RASNIK system for the ATLAS Muon Spectrometer |
title_sort | calibration of a rasnik system for the atlas muon spectrometer |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/684166 |
work_keys_str_mv | AT machefertfp calibrationofarasniksystemfortheatlasmuonspectrometer AT guyotc calibrationofarasniksystemfortheatlasmuonspectrometer AT schullerjp calibrationofarasniksystemfortheatlasmuonspectrometer AT schunep calibrationofarasniksystemfortheatlasmuonspectrometer |