Cargando…

Alignment of irradiated and not irradiated pixel sensors in test-beam operation.

The procedures used to align pixel detectors in test beam operation are presented. Some sensors irradiated up to 10^15 n_eq cm^-2 fluence were operated in partial depletion mode. The effect of a depletion not equal to nominal thickness on the alignment is discussed. An alignment procedure based on t...

Descripción completa

Detalles Bibliográficos
Autor principal: Lari, T
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/684186
_version_ 1780901427547209728
author Lari, T
author_facet Lari, T
author_sort Lari, T
collection CERN
description The procedures used to align pixel detectors in test beam operation are presented. Some sensors irradiated up to 10^15 n_eq cm^-2 fluence were operated in partial depletion mode. The effect of a depletion not equal to nominal thickness on the alignment is discussed. An alignment procedure based on the charge collected by the first pixel in clusters has been developed to allow precise measurement of depletion depth.
id cern-684186
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-6841862019-09-30T06:29:59Zhttp://cds.cern.ch/record/684186engLari, TAlignment of irradiated and not irradiated pixel sensors in test-beam operation.Detectors and Experimental TechniquesThe procedures used to align pixel detectors in test beam operation are presented. Some sensors irradiated up to 10^15 n_eq cm^-2 fluence were operated in partial depletion mode. The effect of a depletion not equal to nominal thickness on the alignment is discussed. An alignment procedure based on the charge collected by the first pixel in clusters has been developed to allow precise measurement of depletion depth.ATL-INDET-2001-002oai:cds.cern.ch:6841862001-04-02
spellingShingle Detectors and Experimental Techniques
Lari, T
Alignment of irradiated and not irradiated pixel sensors in test-beam operation.
title Alignment of irradiated and not irradiated pixel sensors in test-beam operation.
title_full Alignment of irradiated and not irradiated pixel sensors in test-beam operation.
title_fullStr Alignment of irradiated and not irradiated pixel sensors in test-beam operation.
title_full_unstemmed Alignment of irradiated and not irradiated pixel sensors in test-beam operation.
title_short Alignment of irradiated and not irradiated pixel sensors in test-beam operation.
title_sort alignment of irradiated and not irradiated pixel sensors in test-beam operation.
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684186
work_keys_str_mv AT larit alignmentofirradiatedandnotirradiatedpixelsensorsintestbeamoperation