Cargando…

Model of the SCT detectors and electronics for the ATLAS simulation using Geant4

This note presents a model that describes how the SCT detectors and electronics respond to ionization deposited by particles. The model is intended for the digitization of the SCT hits in the future ATLAS simulation using Geant4 and written in C++. The current implementation is limited to barrel mod...

Descripción completa

Detalles Bibliográficos
Autor principal: Gadomski, S
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/684197
_version_ 1780901429684207616
author Gadomski, S
author_facet Gadomski, S
author_sort Gadomski, S
collection CERN
description This note presents a model that describes how the SCT detectors and electronics respond to ionization deposited by particles. The model is intended for the digitization of the SCT hits in the future ATLAS simulation using Geant4 and written in C++. The current implementation is limited to barrel modules. A comparison with beam test data is presented. By tuning the model to the data we find that the calibration scale is accurate within 5% for two barrel modules that were both tested in beam and simulated. The tuned model is able to reproduce the SCT beam test data with sufficient accuracy.
id cern-684197
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-6841972019-09-30T06:29:59Zhttp://cds.cern.ch/record/684197engGadomski, SModel of the SCT detectors and electronics for the ATLAS simulation using Geant4Detectors and Experimental TechniquesThis note presents a model that describes how the SCT detectors and electronics respond to ionization deposited by particles. The model is intended for the digitization of the SCT hits in the future ATLAS simulation using Geant4 and written in C++. The current implementation is limited to barrel modules. A comparison with beam test data is presented. By tuning the model to the data we find that the calibration scale is accurate within 5% for two barrel modules that were both tested in beam and simulated. The tuned model is able to reproduce the SCT beam test data with sufficient accuracy.ATL-SOFT-2001-005oai:cds.cern.ch:6841972001-05-04
spellingShingle Detectors and Experimental Techniques
Gadomski, S
Model of the SCT detectors and electronics for the ATLAS simulation using Geant4
title Model of the SCT detectors and electronics for the ATLAS simulation using Geant4
title_full Model of the SCT detectors and electronics for the ATLAS simulation using Geant4
title_fullStr Model of the SCT detectors and electronics for the ATLAS simulation using Geant4
title_full_unstemmed Model of the SCT detectors and electronics for the ATLAS simulation using Geant4
title_short Model of the SCT detectors and electronics for the ATLAS simulation using Geant4
title_sort model of the sct detectors and electronics for the atlas simulation using geant4
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684197
work_keys_str_mv AT gadomskis modelofthesctdetectorsandelectronicsfortheatlassimulationusinggeant4