Cargando…
Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter
The Module 0 of the electromagnetic end-cap calorimeter was assembled and tested with electron beams in 1999. This note presents the uniformity and the energy resolution obtained in the inner wheel and the crack region (eta=2.5). A constant term of 0.6% (excluding the crack), compatible with the exp...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/684230 |
_version_ | 1780901436071084032 |
---|---|
author | Barrillon, P Djama, F Hinz, L Pralavorio, Pascal |
author_facet | Barrillon, P Djama, F Hinz, L Pralavorio, Pascal |
author_sort | Barrillon, P |
collection | CERN |
description | The Module 0 of the electromagnetic end-cap calorimeter was assembled and tested with electron beams in 1999. This note presents the uniformity and the energy resolution obtained in the inner wheel and the crack region (eta=2.5). A constant term of 0.6% (excluding the crack), compatible with the expectation, is obtained in the inner wheel. Crack effect is mainly sensitive in the region eta=2.5. |
id | cern-684230 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-6842302019-09-30T06:29:59Zhttp://cds.cern.ch/record/684230engBarrillon, PDjama, FHinz, LPralavorio, PascalUniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap CalorimeterDetectors and Experimental TechniquesThe Module 0 of the electromagnetic end-cap calorimeter was assembled and tested with electron beams in 1999. This note presents the uniformity and the energy resolution obtained in the inner wheel and the crack region (eta=2.5). A constant term of 0.6% (excluding the crack), compatible with the expectation, is obtained in the inner wheel. Crack effect is mainly sensitive in the region eta=2.5.ATL-LARG-2001-014oai:cds.cern.ch:6842302001-07-03 |
spellingShingle | Detectors and Experimental Techniques Barrillon, P Djama, F Hinz, L Pralavorio, Pascal Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter |
title | Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter |
title_full | Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter |
title_fullStr | Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter |
title_full_unstemmed | Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter |
title_short | Uniformity scan in the Inner Wheel and the crack between the two wheels (eta=2.5) of the Electromagnetic End-cap Calorimeter |
title_sort | uniformity scan in the inner wheel and the crack between the two wheels (eta=2.5) of the electromagnetic end-cap calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/684230 |
work_keys_str_mv | AT barrillonp uniformityscanintheinnerwheelandthecrackbetweenthetwowheelseta25oftheelectromagneticendcapcalorimeter AT djamaf uniformityscanintheinnerwheelandthecrackbetweenthetwowheelseta25oftheelectromagneticendcapcalorimeter AT hinzl uniformityscanintheinnerwheelandthecrackbetweenthetwowheelseta25oftheelectromagneticendcapcalorimeter AT pralavoriopascal uniformityscanintheinnerwheelandthecrackbetweenthetwowheelseta25oftheelectromagneticendcapcalorimeter |