A first dataflow integration test was performed in April 2001 between the Level-1 Calorimeter Trigger Cluster Processor ROD (CPROD), the RoI Builder (RoIB), and the Readout Sub-System (ROS). The aim of the test was to send RoI information from the CPROD to the RoIB and ROS systems, and to understand...

Descripción completa

Detalles Bibliográficos
Autores principales: Barnett, B M, Dawson, J, Ermoline, E, Gee, CNP, Landon, M P J, Schlereth, J L
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/684255
Descripción
Sumario:A first dataflow integration test was performed in April 2001 between the Level-1 Calorimeter Trigger Cluster Processor ROD (CPROD), the RoI Builder (RoIB), and the Readout Sub-System (ROS). The aim of the test was to send RoI information from the CPROD to the RoIB and ROS systems, and to understand the hardware interface between the systems concentrating on data performance and data integrity. The systems were controlled and monitored by separate diagnostic programs, and software integration within the ATLAS online framework was not included in the goals of these tests.