Cargando…

Performance of an irradiated p-on-n micro prototype VELO detector

A 200 micron thick p-on-n design LHCb PR-02 prototype VELO detector was irradiated and equipped with LHC-speed electronics. This detector was successfully operated in a test-beam and its performance assessed. After an irradiation dose corresponding to between one and two years of LHCb operation the...

Descripción completa

Detalles Bibliográficos
Autores principales: Bowcock, T J V, Buytaert, J, Casse, G, Charles, M J, Dijkstra, H, Collins, P, Dormond, O, Ferro-Luzzi, M, Fiedler, F, Frei, R, Gagliardi, G, Jalocha, P, Libby, J, Ketel, T, Parkes, C, Parzefall, U, Ruf, T, Tareb, M, Teubert, F, Wright, V, Witek, M
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/684441
_version_ 1780901446838910976
author Bowcock, T J V
Buytaert, J
Casse, G
Charles, M J
Dijkstra, H
Collins, P
Dormond, O
Ferro-Luzzi, M
Fiedler, F
Frei, R
Gagliardi, G
Jalocha, P
Libby, J
Ketel, T
Parkes, C
Parzefall, U
Ruf, T
Tareb, M
Teubert, F
Wright, V
Witek, M
author_facet Bowcock, T J V
Buytaert, J
Casse, G
Charles, M J
Dijkstra, H
Collins, P
Dormond, O
Ferro-Luzzi, M
Fiedler, F
Frei, R
Gagliardi, G
Jalocha, P
Libby, J
Ketel, T
Parkes, C
Parzefall, U
Ruf, T
Tareb, M
Teubert, F
Wright, V
Witek, M
author_sort Bowcock, T J V
collection CERN
description A 200 micron thick p-on-n design LHCb PR-02 prototype VELO detector was irradiated and equipped with LHC-speed electronics. This detector was successfully operated in a test-beam and its performance assessed. After an irradiation dose corresponding to between one and two years of LHCb operation the depletion voltage was found to be 320 V, significantly greater than that predicted. The signal-to-noise, at full charge collection efficiency, was found to be 15. The maximum irradiation received was 10^15 protons/cm^2: even after this very high irradiation, charge was still collected albeit with reduced cluster finding efficiency. Particular risks associated with a p-on-n fine pitch detector with a double metal layer are identified. It was shown that at underdepletion the fine pitch p-on-n detector rapidly loses efficiency due to both charge spread and charge loss to the double metal layer.
id cern-684441
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-6844412019-09-30T06:29:59Zhttp://cds.cern.ch/record/684441engBowcock, T J VBuytaert, JCasse, GCharles, M JDijkstra, HCollins, PDormond, OFerro-Luzzi, MFiedler, FFrei, RGagliardi, GJalocha, PLibby, JKetel, TParkes, CParzefall, URuf, TTareb, MTeubert, FWright, VWitek, MPerformance of an irradiated p-on-n micro prototype VELO detectorDetectors and Experimental TechniquesA 200 micron thick p-on-n design LHCb PR-02 prototype VELO detector was irradiated and equipped with LHC-speed electronics. This detector was successfully operated in a test-beam and its performance assessed. After an irradiation dose corresponding to between one and two years of LHCb operation the depletion voltage was found to be 320 V, significantly greater than that predicted. The signal-to-noise, at full charge collection efficiency, was found to be 15. The maximum irradiation received was 10^15 protons/cm^2: even after this very high irradiation, charge was still collected albeit with reduced cluster finding efficiency. Particular risks associated with a p-on-n fine pitch detector with a double metal layer are identified. It was shown that at underdepletion the fine pitch p-on-n detector rapidly loses efficiency due to both charge spread and charge loss to the double metal layer.LHCb-2001-040oai:cds.cern.ch:6844412001-05-22
spellingShingle Detectors and Experimental Techniques
Bowcock, T J V
Buytaert, J
Casse, G
Charles, M J
Dijkstra, H
Collins, P
Dormond, O
Ferro-Luzzi, M
Fiedler, F
Frei, R
Gagliardi, G
Jalocha, P
Libby, J
Ketel, T
Parkes, C
Parzefall, U
Ruf, T
Tareb, M
Teubert, F
Wright, V
Witek, M
Performance of an irradiated p-on-n micro prototype VELO detector
title Performance of an irradiated p-on-n micro prototype VELO detector
title_full Performance of an irradiated p-on-n micro prototype VELO detector
title_fullStr Performance of an irradiated p-on-n micro prototype VELO detector
title_full_unstemmed Performance of an irradiated p-on-n micro prototype VELO detector
title_short Performance of an irradiated p-on-n micro prototype VELO detector
title_sort performance of an irradiated p-on-n micro prototype velo detector
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684441
work_keys_str_mv AT bowcocktjv performanceofanirradiatedponnmicroprototypevelodetector
AT buytaertj performanceofanirradiatedponnmicroprototypevelodetector
AT casseg performanceofanirradiatedponnmicroprototypevelodetector
AT charlesmj performanceofanirradiatedponnmicroprototypevelodetector
AT dijkstrah performanceofanirradiatedponnmicroprototypevelodetector
AT collinsp performanceofanirradiatedponnmicroprototypevelodetector
AT dormondo performanceofanirradiatedponnmicroprototypevelodetector
AT ferroluzzim performanceofanirradiatedponnmicroprototypevelodetector
AT fiedlerf performanceofanirradiatedponnmicroprototypevelodetector
AT freir performanceofanirradiatedponnmicroprototypevelodetector
AT gagliardig performanceofanirradiatedponnmicroprototypevelodetector
AT jalochap performanceofanirradiatedponnmicroprototypevelodetector
AT libbyj performanceofanirradiatedponnmicroprototypevelodetector
AT ketelt performanceofanirradiatedponnmicroprototypevelodetector
AT parkesc performanceofanirradiatedponnmicroprototypevelodetector
AT parzefallu performanceofanirradiatedponnmicroprototypevelodetector
AT ruft performanceofanirradiatedponnmicroprototypevelodetector
AT tarebm performanceofanirradiatedponnmicroprototypevelodetector
AT teubertf performanceofanirradiatedponnmicroprototypevelodetector
AT wrightv performanceofanirradiatedponnmicroprototypevelodetector
AT witekm performanceofanirradiatedponnmicroprototypevelodetector