Single event effects actel AX FPGA

ACTEL and NASA performed irradiation tests at Brookhaven National Laboratory on the AX1000 component of the new ACTEL FPGA family "Axcelerator". The characteristics of these FPGAs are attractive and make them good candidates for the Front-End of the LHCb Calorimeters. The results of the me...

Descripción completa

Detalles Bibliográficos
Autor principal: Machefert, F P
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/684477
_version_ 1780901454797602816
author Machefert, F P
author_facet Machefert, F P
author_sort Machefert, F P
collection CERN
description ACTEL and NASA performed irradiation tests at Brookhaven National Laboratory on the AX1000 component of the new ACTEL FPGA family "Axcelerator". The characteristics of these FPGAs are attractive and make them good candidates for the Front-End of the LHCb Calorimeters. The results of the measurements done at BNL are used to determine the resistance of the AX in the environment of the Calorimeter electronics. If mitigation techniques are used (triple voting or horizontal and vertical parity), no major worry is expected in spite of the safety factors applied in the evaluation. In this case and at maximum, a few bit errors could be observed per year on the full Calorimeter system.
id cern-684477
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6844772019-09-30T06:29:59Zhttp://cds.cern.ch/record/684477engMachefert, F PSingle event effects actel AX FPGADetectors and Experimental TechniquesACTEL and NASA performed irradiation tests at Brookhaven National Laboratory on the AX1000 component of the new ACTEL FPGA family "Axcelerator". The characteristics of these FPGAs are attractive and make them good candidates for the Front-End of the LHCb Calorimeters. The results of the measurements done at BNL are used to determine the resistance of the AX in the environment of the Calorimeter electronics. If mitigation techniques are used (triple voting or horizontal and vertical parity), no major worry is expected in spite of the safety factors applied in the evaluation. In this case and at maximum, a few bit errors could be observed per year on the full Calorimeter system.LHCb-2002-072oai:cds.cern.ch:6844772002-12-20
spellingShingle Detectors and Experimental Techniques
Machefert, F P
Single event effects actel AX FPGA
title Single event effects actel AX FPGA
title_full Single event effects actel AX FPGA
title_fullStr Single event effects actel AX FPGA
title_full_unstemmed Single event effects actel AX FPGA
title_short Single event effects actel AX FPGA
title_sort single event effects actel ax fpga
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684477
work_keys_str_mv AT machefertfp singleeventeffectsactelaxfpga