Cargando…

The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources

A calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data di...

Descripción completa

Detalles Bibliográficos
Autores principales: Boccardi, A, Buytaert, J, Collins, P, Libby, J, Parzefall, U, De Paula, B
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/684486
_version_ 1780901456580182016
author Boccardi, A
Buytaert, J
Collins, P
Libby, J
Parzefall, U
De Paula, B
author_facet Boccardi, A
Buytaert, J
Collins, P
Libby, J
Parzefall, U
De Paula, B
author_sort Boccardi, A
collection CERN
description A calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data distribution, while the other reconstructs the SCT128A pulse-shape. The results are found to be compatible. In addition, the results are in agreement with previous test-beam measurements.
id cern-684486
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-6844862019-09-30T06:29:59Zhttp://cds.cern.ch/record/684486engBoccardi, ABuytaert, JCollins, PLibby, JParzefall, UDe Paula, BThe calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sourcesDetectors and Experimental TechniquesA calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data distribution, while the other reconstructs the SCT128A pulse-shape. The results are found to be compatible. In addition, the results are in agreement with previous test-beam measurements.LHCb-2002-035oai:cds.cern.ch:6844862002-06-18
spellingShingle Detectors and Experimental Techniques
Boccardi, A
Buytaert, J
Collins, P
Libby, J
Parzefall, U
De Paula, B
The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
title The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
title_full The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
title_fullStr The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
title_full_unstemmed The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
title_short The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
title_sort calibration of the sct128a asic signal-to-noise performance using am241 and co57 radioactive sources
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/684486
work_keys_str_mv AT boccardia thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT buytaertj thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT collinsp thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT libbyj thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT parzefallu thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT depaulab thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT boccardia calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT buytaertj calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT collinsp calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT libbyj calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT parzefallu calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources
AT depaulab calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources