The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources
A calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data di...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/684486 |
_version_ | 1780901456580182016 |
---|---|
author | Boccardi, A Buytaert, J Collins, P Libby, J Parzefall, U De Paula, B |
author_facet | Boccardi, A Buytaert, J Collins, P Libby, J Parzefall, U De Paula, B |
author_sort | Boccardi, A |
collection | CERN |
description | A calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data distribution, while the other reconstructs the SCT128A pulse-shape. The results are found to be compatible. In addition, the results are in agreement with previous test-beam measurements. |
id | cern-684486 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-6844862019-09-30T06:29:59Zhttp://cds.cern.ch/record/684486engBoccardi, ABuytaert, JCollins, PLibby, JParzefall, UDe Paula, BThe calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sourcesDetectors and Experimental TechniquesA calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data distribution, while the other reconstructs the SCT128A pulse-shape. The results are found to be compatible. In addition, the results are in agreement with previous test-beam measurements.LHCb-2002-035oai:cds.cern.ch:6844862002-06-18 |
spellingShingle | Detectors and Experimental Techniques Boccardi, A Buytaert, J Collins, P Libby, J Parzefall, U De Paula, B The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources |
title | The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources |
title_full | The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources |
title_fullStr | The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources |
title_full_unstemmed | The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources |
title_short | The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources |
title_sort | calibration of the sct128a asic signal-to-noise performance using am241 and co57 radioactive sources |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/684486 |
work_keys_str_mv | AT boccardia thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT buytaertj thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT collinsp thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT libbyj thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT parzefallu thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT depaulab thecalibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT boccardia calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT buytaertj calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT collinsp calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT libbyj calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT parzefallu calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources AT depaulab calibrationofthesct128aasicsignaltonoiseperformanceusingam241andco57radioactivesources |