Cargando…

The calibration of the SCT128A ASIC signal-to-noise performance using Am241 and Co57 radioactive sources

A calibration of a detector equipped with SCT128A ASICs using Am^241 and Co^57 sources to find the signal-to-noise for a most probable Minimum Ionising Particle (MIP) signal, in 300 micron thick silicon, is presented. Two different analyses are used. One analysis uses a simulation to fit the data di...

Descripción completa

Detalles Bibliográficos
Autores principales: Boccardi, A, Buytaert, J, Collins, P, Libby, J, Parzefall, U, De Paula, B
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/684486